WIRING INSTRUCTIONS:

 

MAKING FINAL ELECTRICAL CONNECTIONS 

 HARDWIRED 

1. 

WIRING THROUGH HOLE IN HOUSING

:  IDENTIFY AND REMOVE CAP AT SELECTED END OF HOUSING.  EXTEND BUILDING POWER WIRING TO FIXTURE 

AND FEED THROUGH OPENING.  PROVIDE UL/ETL APPROVED WATER TIGHT STRAIN RELIEF. 

2. 

 REMOVE 

LENS (SEE “LENS REMOVAL AND REPLACEMENT”) AND LOWER/REMOVE TRAY

.  TAKE CARE NOT TO  DAMAGE THE FIXTURE. TRAY IS 

CAPTIVE AND  WILL FREELY HANG OPEN (HANDS FREE). 

3. 

MAKE FINAL ELECTRICAL CONNECTIONS

 INSIDE HOUSING  PER ALL APPLICABLE CODES - BLACK TO BLACK (HOT/LINE/LIVE); WHITE  TO WHITE (NEUTRAL) 

AND GREEN (OR BARE) TO GREEN (GROUND). MAKE SURE ELECTRICAL CONNECTIONS ARE SECURE AND  ENSURE  NO  BARE WIRES  ARE 
EXPOSED. 

4. 

DIMMING (IF APPLICABLE):

  MAKE FINAL ELECTRICAL CONNECTIONS  INSIDE WIREWAY PER ALL APPLICABLE CODES 

 VIOLET TO VIOLET (DIM +), 

GREY TO GREY (DIM -).   MAKE SURE ELECTRICAL CONNECTIONS ARE CONTINUOUS AND  ENSURE  NO  BARE  WIRES  ARE EXPOSED.     

5. 

EMERGENCY BATTERY BACKUP (EMB) OPTION (WITH SWITCH LEG): MAKE FINAL ELECTRICAL CONNECTIONS INSIDE WIREWAY PER ALL 
APPLICABLE

 CODES - BLACK TO BLACK (HOT/LINE/LIVE); RED (SWITCH LEG) TO BLACK/RED; WHITE  TO WHITE (NEUTRAL) AND GREEN (OR BARE) TO 

GREEN (GROUND). MAKE SURE ELECTRICAL CONNECTIONS ARE SECURE AND  ENSURE NO  BARE WIRES  ARE EXPOSED.   

6. 

EMERGENCY BATTERY BACKUP (EMB) OPTION (WITHOUT SWITCH LEG):

 MAKE FINAL ELECTRICAL CONNECTIONS INSIDE WIREWAY  PER ALL APPLICABLE 

CODES - BLACK TO BLACK (HOT/LINE/LIVE); REMOVE WAGO FROM FIXTURE BLACK/RED WIRE AND PLACE FIXTURE BLACK/RED WIRE IN WAGO WITH 
BLACK WIRES (HOT/LINE/LIVE); WHITE  TO WHITE (NEUTRAL) AND GREEN (OR BARE) TO GREEN (GROUND). MAKE SURE ELECTRICAL 
CONNECTIONS ARE SECURE AND ENSURE NO  BARE WIRES  ARE  EXPOSED.     

7. 

NEATLY ARRANGE

 WIRES IN HOUSING.  PAY CLOSE ATTENTION ALL WIRES AND  CONNECTIONS ARE PROPERLY LAYING INSIDE  FIXTURE HOUSING  BEFORE 

CLOSING.   

8. 

CLOSE AND ATTACH TRAY:

 

PRESS THE TRAY INTO THE CLIPS UNTIL A POSITIVE “CLICK” IS HEARD.  

 

9. 

PROPERLY SEAT LENS

 ON GASKET ON HOUSING. 

10. 

BUCKLE ALL LATCHES ON LENS.  

11. 

PLACE 2 SAFETY SCREWS (INCLUDED, IF APPLICABLE), 1 EACH ON OPPOSING SIDES TO PREVENT UNAUTHORIZED TAMPERING. 

12. 

TURN ELECTRICITY ON AT THE CIRCUIT BREAKER,  PANELBOARD, OR FUSE BOX 

 

FIXTURE SHOULD ILLUMINATE.  IF IT DOESN’T, REFER TO 

TROUBLESHOOTING INSTRUCTIONS OR CALL TECHNICAL SUPPORT (913-851-3000). 

 
MAKING FINAL ELECTRICAL CONNECTIONS 

 FIXTURES WITH OPTIONAL FACTORY INSTALLED CORD (CORD/PLUG): 

13. 

FIXTURES WITH CORD AND NO PLUG (WIRE ENDS):   

a.

 

MAKE FINAL ELECTRICAL CONNECTIONS PER  ALL APPLICABLE CODES - BLACK TO BLACK (HOT); WHITE TO WHITE  (NEUTRAL) AND GREEN (OR BARE) 
TO GREEN (GROUND).  

b.

 

EXTEND CORD WITH WIRE ENDS TO  NEAREST ELECTRICAL JUNCTION BOX (PROVIDED BY CONTRACTOR)  AND ENSURE NO BARE WIRES ARE 
EXPOSED. 

14. 

FIXTURE WITH CORD AND  PLUG:  

a.

 

EXTEND CORD AND PLUG TO NEAREST APPROPRIATELY  RATED RECEPTACLE (PROVIDED BY CONTRACTOR) AND CONNECT. 

 

 

MANUFACTURER WARNINGS FOR EMERGENCY BATTERY BACKUP (EMB): 

1.

 

IMPORTANT

:  INDICATOR (LED LIGHT) ILLUMINATED INDICATES BATTERY IN CHARGE MODE WHEN AC POWER IS APPLIED. IT IS RECOMMENDED AND 

REQUIRED BY APPLICABLE CODE TO TEST EMERGENCY BALLAST TO ENSURE PROPER FUNCTION OF THE SYSTEM; PUSH THE TEST SWITCH FOR THIRTY 
(30) SECONDS EVERY 30 DAYS TO ENSURE THE EMERGENCY DRIVER IS 

a.

 

FUNCTIONING AS LED LIGHT SOURCE ILLUMINATED. CONDUCT A NINETY MINUTE (90) DISCHARGE TEST ONE TIME (1) PER YEAR LED LIGHT 
SOURCE SHOULD BE ILLUMINATED FOR A MINIMUM OF NINETY MINUTES (90). 

2.

 

TESTING SYSTEM

:  THE EMERGENCY BATTERY REQUIRES A CHARGE MINIMUM OF ONE (1) HOUR BEFORE TESTING THE CIRCUIT. 

a.

 

A FULL CHARGE REQUIRES THIRTY-TWO (32) HOURS. 

3.

 

CAUTION

: DO NOT MOUNT EMB FIXTURES NEAR GAS OR ELECTRIC HEATERS. 

4.

 

CAUTION

: BATTERY IS RECHARGEABLE NiCad TYPE AND MUST BE RECYCLED OR DISPOSED OF PROPERLY. 

5.

 

SERVICING SHOULD ONLY BE PERFORMED BY QUALIFIED SERVICE PERSONNEL.  DO NOT USE THIS EMERGENCY DRIVER FOR OTHER THAN INTENDED USE. 

EQUIPMENT SHOULD BE MOUNTED IN LOCATIONS AND AT HEIGHTS WHERE IT WILL NOT READILY BE SUBJECTED TO TAMPERING BY UNAUTHORIZED 
PERSONNEL. 

Содержание HD20S-A1-06K-2N Series

Страница 1: ...2W xx xx CL 13 F to 113 F 25 C to 35 C GENERAL NOTES 1 MAKE SURE ALL WIRE AND CONNECTORS ARE UL LISTED IF THE ELECTRICAL SYSTEM CONTAINS NO GROUNDING WIRE CONSULT WITH A QUALIFIED ELECTRICIAN BEFORE PROCEEDING WITH THE INSTALLATION 2 SUSPENSION CABLE OR CHAIN SHALL BE RATED TO SUPPORT WEIGHT OF FIXTURE S INCLUDING ALL ACCESSORIES AND OPTIONS AIRCRAFT SUSPENSION CABLE MAY BE ORDERED SEPARATELY FROM...

Страница 2: ...UX EMPLACEMENTS MOUILLÉS S24 L2 Account for small parts and destroy packing material as these maybe hazardous to children Caution Risk of electric shock ALL LATCHES MUST REMAIN IN PLACE IN ORDER TO MAINTAIN RAIN TIGHT BONDING IS NOT AUTOMATIC AND MUST BE PROVIDED AS A PART OF THE INSTALLATION For indoor and outdoor applications Turn power off before servicing see instructions Properly ground fixtu...

Страница 3: ...EDIATELY CONTACT LIGHTING TECH FLEX COM 6 TURN OFF ELECTRICITY AT THE MAIN CIRCUIT BREAKER PANELBOARD FUSE BOX OR DISCONNECT DO NOT ATTEMPT TO INSTALL FIXTURE WITH THE POWER ON 7 MAKE SURE THE MOUNTING SURFACE IS CAPABLE OF SUPPORTING WEIGHT OF FIXTURE 8 MAX AMBIENT REDUCED 5 C WHEN MOUNTED NEAR CEILING 9 ENSURE PROPER AIRFLOW AROUND FIXTURE CABLE READY MOUNT PREPARING TO INSTALL 1 REFER TO GENERA...

Страница 4: ...GENERAL INSTRUCTIONS AT THE BEGINNING OF THIS SECTION 2 MEASURE SPACING BETWEEN BRACKETS TRANSFER MEASUREMENT FROM FIXTURE TO MOUNTING SURFACE FIG 3 BRACKETS SHOULD BE SPACED AT LEAST 18 O C FOR 2N MODEL 36 O C FOR 4N MODEL 3 REMOVE MOUNTING BRACKETS FROM FIXTURE HOUSING REMOVE BAIL HOOK OR LAY BAIL HOOK TO ONE SIDE FIG 4 4 ATTACH BRACKET TO MOUNTING SURFACE 5 RAISE FIXTURE TO MOUNTING BRACKETS AN...

Страница 5: ...ACCESSORY 45M 2N AND 4N MODELS ONLY PREPARING TO INSTALL 1 REFER TO GENERAL INSTRUCTIONS AT THE BEGINNING OF THIS SECTION 2 BRACKETS SHOULD BE SPACED AT LEAST 18 APART FOR 2N MODEL 36 APART FOR 4N MODEL 3 MEASURE DESIRED SPACING BETWEEN BRACKETS TRANSFER MEASUREMENT MOUNTING SURFACE FIG 7 4 ATTACH BRACKET TO MOUNTING SURFACE FIG 8 5 RAISE FIXTURE TO MOUNTING BRACKETS AND SECURE IN PLACE FIG 9 6 MA...

Страница 6: ... 082318 SURFACE MOUNT FM2WSS 2W MODEL ONLY PREPARING TO INSTALL 1 REFER TO GENERAL INSTRUCTIONS AT THE BEGINNING OF THIS SECTION 2 MEASURE SPACING BETWEEN BRACKETS TRANSFER MEASUREMENT FROM FIXTURE TO MOUNTING SURFACE BRACKETS ARE SPACED AT 17 O C FOR 2W 3 ATTACH BRACKET TO MOUNTING SURFACE 4 RAISE FIXTURE TO MOUNTING BRACKETS AND SECURE IN PLACE FIG 9 5 MAKE FINAL WIRING CONNECTIONS REFER TO WIRI...

Страница 7: ...MLT BRACKET PROVIDED BY FLS ACCEPTS 1 4 THREADED ROD 3 REMOVE MOUNTING BRACKETS FROM FIXTURE HOUSING REMOVE BAIL HOOK OR LAY BAIL HOOK TO ONE SIDE FIG 11 4 LOCATE EXISTING THREADED ROD IF APPLICABLE AND SECURELY ATTACH BRACKET TO THREADED ROD IF THREADED ROD NOT PRESENT PROVIDE STEMS AND FASTENERS NOT INCLUDED AND SECURELY ATTACH BRACKET FIG 12 5 BRACKETS SHOULD BE SPACED AT LEAST 18 O C FOR 2N MO...

Страница 8: ...UNTING SURFACE THIS MEASUREMENT IS HOW FAR APART THE NEW PENDANTS SHALL BE SPACED BRACKETS ARE SPACED AT 17 O C FOR 2W 4 FOR EXISTING PENDANT ENSURE PENDANT SPACING MATCHES BRACKET LOCATION ON FIXTURE FIG 15 5 REMOVE BRACKET AND OPERATORS FROM PACKAGING 2 OPERATORS PROVIDED WITH EACH BRACKET 6 REMOVE MOUNTING TAB FROM FIXTURE HOUSING ATTACH OPERATOR PIECE TO TAB AND REINSTALL TAB 4 TIMES FIG 16 7 ...

Страница 9: ...KE SURE THE RIGID STEM IS CAPABLE OF SUPPORTING WEIGHT OF FIXTURE 3 RAISE PLATE TO RIGID STEM 4 THREAD WASHER PROVIDED BY CONTRACTOR ONTO BOTTOM OF THREADED RIGID STEM SECURING PLATE IN PLACE FINGER TIGHTEN THEN USE WRENCH TO SECURELY TIGHTEN LOCKNUT 5 ATTACH SUSPENTION CABLES FOUR 4 SUPPLIED TO ALL FOUR 4 MOUNTING TABS FOR 2W OR TWO 2 TO BOTH MOUNTING RINGS FOR 2N 4N ON FIXTURE AND ON MOUNTING HO...

Страница 10: ...T SEPARATELY ORDERED ACCESSORY HANGERSS 2W ONLY PREPARING TO INSTALL 7 REFER TO GENERAL INSTRUCTIONS AT THE BEGINNING OF THIS SECTION 8 ENSURE SUSPENSION CABLE ORDERED SEPARATELY CABLEKIT2P OR CABLEKIT2PSS OR EXISTING CABLE OR CHAIN NOT INCLUDED IS SECURED TO STRUCTURE 9 ATTACH CABLES TO HANGERS 10 RAISE FIXTURE TO HANGER AND ATTACH TO FIXTURE THROUGH FOUR 4 MOUNTING TABS FIG 18 11 MAKE FINAL WIRI...

Страница 11: ... AT THE BEGINNING OF THIS SECTION 2 REMOVE RUBBER CAP FIG 19 3 REMOVE LENS SEE LENS REMOVAL AND REPLACEMENT BELOW AND LOWER REMOVE TRAY FIG 23 4 INSERT POWER CORD THROUGH APPROPRIATE SEALING OR WATER TIGHT CORD GRIP PROVIDED BY CONTACTOR FIG S 20 AND 21 5 PULL THE CORD INTO FIXTURE A MINIMUM OF 6 6 TIGHTEN CORD GRIP PER CORD GRIP INSTRUCTIONS ENSURING A WATERTIGHT SEAL FIG 22 7 MAKE FINAL WIRING C...

Страница 12: ...NS 1 REFER TO GENERAL INSTRUCTIONS AT THE BEGINNING OF THIS SECTION 2 IF INSTALLED REMOVE 2 SAFETY SCREWS 1 EACH ON OPPOSING SIDES 3 UNBUCKLE ALL LATCHES ON LENS FIG 24 4 REMOVE LENS REPLACING LENS 1 REFER TO GENERAL INSTRUCTIONS AT THE BEGINNING OF THIS SECTION 2 PROPERLY SEAT LENS ON GASKET ON HOUSING FIG 25 3 BUCKLE ALL LATCHES ON LENS 4 PLACE 2 SAFETY SCREWS INCLUDED IF APPLICABLE 1 EACH ON OP...

Страница 13: ...UTIONS COM LIGHTING TECH FLEXTRONICS COM 913 851 3000 REV 082318 WATERPROOF SLEEVE INSTALLATION ORDERED AS AN OPTION WPSLV PREPARING TO INSTALL 1 ONLY USED FOR CORD AND PLUG APPLICATIONS 2 STRETCH SLEEVE OVER PLUG SOCKET FIG 26 3 PLUG CORD INTO SOCKET PROVIDED BY CONTRACTOR 4 SLEEVE SHOULD PRESS FIRMLY AGAINST THE SOCKET CREATING A SEAL FIG 27 Plot PLUG WITH SLEEVE ATTACHED TO SOCKET FIG 26 FIG 27...

Страница 14: ...ONS ARE PROPERLY LAYING INSIDE FIXTURE HOUSING BEFORE CLOSING 8 CLOSE AND ATTACH TRAY PRESS THE TRAY INTO THE CLIPS UNTIL A POSITIVE CLICK IS HEARD 9 PROPERLY SEAT LENS ON GASKET ON HOUSING 10 BUCKLE ALL LATCHES ON LENS 11 PLACE 2 SAFETY SCREWS INCLUDED IF APPLICABLE 1 EACH ON OPPOSING SIDES TO PREVENT UNAUTHORIZED TAMPERING 12 TURN ELECTRICITY ON AT THE CIRCUIT BREAKER PANELBOARD OR FUSE BOX FIXT...

Страница 15: ...OWN SERIES IMPORTANT READ ALL INSTRUCTIONS THOUROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF ESSENTIALS SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE FLEXLIGHTINGSOLUTIONS COM LIGHTING TECH FLEXTRONICS COM 913 851 3000 REV 082318 ...

Страница 16: ...T BOUNCE OFF OF NEARBY SURFACES AND RETURN TO THE SENSOR MOTION IN THE AREA CHANGES THE SPEED OF THE WAVES RETURNING TO THE SENSOR THE SENSOR DETECTS THE CHANGE AND INTERPRETS IT AS OCCUPANCY THIS CAUSES THE SENSOR TO TURN ON THE LOAD HIGH FREQUENCY RADIO WAVES CAN PENETRATE CERTAIN MATERIALS THEREFORE THE FM 105 CAN BE INSTALLED BEHIND A LUMINARIES PLASTIC OR GLASS LENS THE FM 105 CAN BE USED IN ...

Страница 17: ... MOVE WITHIN THE DETECTION AREA OF THE SENSOR IF THE LOAD COMES BACK ON YOU NEED TO REPEAT THE PROCEDURE IMPORTANT STARTUP INFORMATION THE FIRST TIME THE SENSOR IS POWERED UP THE LOAD WILL FLASH ON THEN OFF ONCE THEN THERE WILL BE 10 SECONDS WHILE THE SENSOR WARMS UP AFTER THAT TIME THE SENSOR WILL WORK NORMALLY TROUBLESHOOTING TO QUICKLY TEST THE UNIT TURN THE TIME DELAY TO MINIMUM MOVE OUT OF TH...

Отзывы: