1. SAFETY PRECAUTIONS

 Be sure to read the instructions in this section carefully before use.
 Make sure to observe the instructions in this manual as the conventions of safety symbols and messages
 regarded as very important precautions are included.
 We also recommend you keep this instruction manual handy for future reference.

Safety Symbol and Message Conventions

Safety symbols and messages described below are used in this manual to prevent bodil y injury and property 
damage which could result from mishandling. Before operating your product, read this manual first and
understand the safety symbols and messages so you are thoroughly aware of the potential safety 

Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.

Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.

 Do not place cups, bowls, or other containers of
 liquid or metallic objects on top of the unit. If they 
 accidentally spill into the unit, this may cause a
 fire or electric shock.

  Do not insert nor drop metallic objects or flammable
  materials in the ventilation slots of the unit's cover, 
  as this may result in fire or electric shock.

When Installing the Unit

When Installing the Unit

   Should the following irregularity be found during 
   

use, immediately switch off the power, disconnect

   

the power supply plug from the AC outlet and contact

   

y our nearest  dealer. Make no further 

attempt to op-

   erate the unit in this condition as this 

may cause 

   fire or electric shock.
      If you detect smoke or a strange smell coming
      from the unit.
      If water or any metallic object gets into the unit
      If the unit falls, or the unit case breaks
      If the power supply cord is damaged (exposure 
      of the core, disconnection, etc.)
      If it is malfunctioning (no tone sounds.)

   To prevent a fire or electric shock, never open nor
   remove the unit case as there are high voltage 
   components inside the unit. Refer all servicing 
   to your nearest dealer.

   

Do not expose the unit to rain or an environment

   

where it may be splashed by water or other liquids,

 

   as doing so may result in fire or electric shock.

   Use the unit only with the voltage  specified on 
   the unit.Using a voltage higher than that which
   is specified may result in fire or electric shock.

   

Do not cut,kink otherwise damage nor modify the

   power supply cord. In addition, avoid using the 
   

power cord in close proximity to heaters, and never 

   

place heavy objects - including the unit itself - on

   the power cord, as doing so may  result in fire  or

   electric shock.

 

Be sure to replace the unit's terminal cover after

 connection completion. Because high voltage
 is 

applied to the speaker terminals, never touch

 these 

terminals to avoid electric shock.

 Be sure to ground to the safety  ground (earth)
 terminal to avoid electric shock. Never ground 

to a gas pipe as a catastrophic disaster may result.

 

Avoid installing or mounting  the unit in  unstable

 

locations, such as on a rickety table or  a slanted

surface. Doing so may result in the unit  falling 

down,causing personal injury and / or property

 

 damage.

Содержание FLP-ZS9812 MKII

Страница 1: ...use the zone selector switches on the unit will be temporarily deactivated muting the BGM along the way FLP ZS 9812 MKII 12 Channel Zone Selector An ALL CALL button for simultaneous activation of all...

Страница 2: ...resultsfrom this unit We also recommend that you keep this manual handyfor future reference PUBLIC ADDRESS SYSTEM TM TM ZONE SELECTOR FLP ZS9812MKII OPERATION MANUAL OVERRIDE 1 2 3 4 5 6 7 8 9 10 11...

Страница 3: ...2MKII 2 TABLE OF CONTENTS 1 SAFETY PRECAUTIONS 3 2 FEATURES 5 3 NOMENCLATURE AND FUNCTIONS 3 1 Front Panel 6 3 2 Rear Panel 7 4 MACHINE OPERATION 8 5 APPLICATIONS 9 6 SPECIFICATIONS 10 7 DIMENSIONAL D...

Страница 4: ...nd contact y our nearest dealer Make no further attempt to op erate the unit in this condition as this may cause fire or electric shock If you detect smoke or a strange smell coming from the unit If w...

Страница 5: ...bjects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Make sure...

Страница 6: ...titions with the region control 2 12 amplifier audio signal input 12 outputs one correspondence 3 Can be remote control district the region features 4 With a short circuit signal control function of t...

Страница 7: ...he board did not signal output 3 NOMENCLATURE AND FUNCTIONS 1 3 1 FRONT PANEL FLP ZS9812MKII 2 3 2 Zoning button Zoning indicator 3 ALL CALL All zoning button All zoning indicator OVERRIDE 1 2 3 4 5 6...

Страница 8: ...8 100V COM AMP11 100V COM ZONE11 100V COM AMP12 100V COM ZONE12 100V COM REMOTE SELECT PIN 1 Z7 PIN 2 Z8 PIN 3 Z9 PIN 4 Z10 PIN 5 Z11 PIN 6 Z12 PIN 7 AC PIN 8 GND AMPLIFIER INPUTS ZONE OUTPUTS FOR ZO...

Страница 9: ...PIN1 PIN6s aid control ZONE7 ZON12 PIN1 6 and GND shorted to trigger connected ZON7 12 the input and output channels corresponding to 11 can be connected panel indicator light does not shine c PIN7 A...

Страница 10: ...PR AMP 1 100V COM ZONE 1 100V COM AMP 2 100V COM ZONE 2 100V COM AMP 3 100V COM ZONE 3 100V COM AMP 4 100V COM ZONE 4 100V COM AMP 5 100V COM ZONE 5 100V COM AMP 6 100V COM ZONE 6 100V COM AMP 9 100V...

Страница 11: ...10 6 SPECIFICATIONS MODEL FLP ZS9812MKII AUDIO OUTPUT 100V AUDIO INPUT 100V FLP ZS9812MKII AUDIO AMPLIFIER RECEIVER MODULE DIMENSION mm WEIGHT 484X132X44 POWER REQUIREMENTS DC 24V 1 9kg...

Страница 12: ...5 Z5 PIN 6 Z6 PIN 7 AC PIN 8 PR AMP 1 100V COM ZONE 1 100V COM AMP 2 100V COM ZONE 2 100V COM AMP 3 100V COM ZONE 3 100V COM AMP 4 100V COM ZONE 4 100V COM AMP 5 100V COM ZONE 5 100V COM AMP 6 100V C...

Страница 13: ...PUBLIC ADDRESS SYSTEM VersionV0 1 TM TM...

Отзывы: