Commissioning
6
In order to ensure safe commissioning, carry out various tests prior to commissioning.
Testing before commissioning
WARNING
Danger
Overload conditions can occur during the commissioning of the coupling. The coupling can
burst and metal parts can be flung out. There is a risk of fatal injury from flying fragments.
● Carry out the tests prior to commissioning.
● Do not touch the rotating coupling.
1. Check the tightening torques of the screws of the coupling in accordance with section
Tightening torques and widths A/F (Page 63).
2. Check the tightening torques of the foundation bolts of the coupled machines.
3. Check whether the enclosures (coupling guard, touch protection) have been installed and
that the function of the coupling has not been adversely affected by the enclosure. This
also applies to test runs and rotational direction checks.
BIPEX-S 3410en
Operating Instructions 10/2017
31
Содержание BCC
Страница 1: ...FLENDER COUPLINGS BIPEX S Operating Instructions 3410en Edition 10 2017 BNN BGG BCC BHH BKK BCS BHH W ...
Страница 2: ...21 09 2017 12 18 V6 00 ...
Страница 10: ...Introduction 1 3 Copyright BIPEX S 3410en 10 Operating Instructions 10 2017 ...
Страница 14: ...Safety instructions 2 3 General warning notices BIPEX S 3410en 14 Operating Instructions 10 2017 ...
Страница 22: ...Description BIPEX S 3410en 22 Operating Instructions 10 2017 ...
Страница 32: ...Commissioning BIPEX S 3410en 32 Operating Instructions 10 2017 ...
Страница 38: ...Operation 7 2 Faults causes and rectification BIPEX S 3410en 38 Operating Instructions 10 2017 ...
Страница 44: ...Service and support 9 1 Contact BIPEX S 3410en 44 Operating Instructions 10 2017 ...
Страница 46: ...Disposal BIPEX S 3410en 46 Operating Instructions 10 2017 ...
Страница 65: ......