07-7
Electrical Systems
Generator Cooling System
The generator is liquid cooled. The cooling sys-
tem includes a radiator, cooling fan, water
pump, a coolant reservoir/recovery container,
and is similar to an automotive engine cooling
system.
Check and maintain the coolant level at the
coolant recovery container located on the front
of the generator.
Generator Slide-Out
(If Equipped)
The generator may be mounted on a slide-out
cradle.
Generator Maintenance
Refer to the generator manufacturer's informa-
tion in the
Owner's Information Package
for
details on generator operation and maintenance.
Automatic Generator Start
Control System
(If Equipped)
The Automatic Generator Start Control System
(AGS) performs two distinct functions:
1. Start the auxiliary generator automati-
cally in response to low battery voltage.
*The AGS continuously monitors the coach
battery system and will start the generator
automatically when one "bar" is displayed
on the battery level indicator.
2. Start the auxiliary generator automati-
cally in response to air conditioning
requests.
*The AGS continuously monitors the thermo-
stat of the air conditioning system and starts
the auxiliary generator, if the temperature
rises to the preset level requiring conditioning.
Main Features
(Automatic Gen. Start)
Easy to use push button operation controls all
functions of the AGS.
Time is indicated to the hour by an internal real
time clock. Quiet time periods can be entered in
hours to prevent automatic operation of the aux-
iliary generator during inappropriate times.
Hours may be set either for AM or PM.
A Time Zone indicator is provided for easy
changing of local time when traveling.
NOTE
For detailed information on how to use the Automatic
Generator Start Control System see the
Ownerʼs
Information Package
.
CAUTION
Do not check the coolant system at the radiator cap
when the generator is hot. Check the system at the
coolant recovery container
only.
!
WARNING
Keep all obstacles and body parts clear of the gener-
ator and slide-out mechanism when extending or
retracting the generator.
!
WARNING
Exhaust gases are deadly. Inspect the generator
exhaust system thoroughly before starting the gener-
ator engine. Do not block the tail pipe or situate the
motor home in a place where the exhaust gases have
any possibility of accumulating either outside, under-
neath, or inside your vehicle or any nearby vehicles.
Outside air movements can carry exhaust gases
inside the vehicle through windows or other openings
remote from the generator exhaust. Operate the gen-
erator only when safe dispersion of exhaust gases
can be assured, and monitor outside conditions to be
sure that exhaust gases continue to be dispersed
safely.
!
Содержание 2011 American Eagle
Страница 18: ...03 2 Eagle and Tradition Information DRIVER S CONTROLS Instrument Panel...
Страница 48: ...This page intentionally blank...
Страница 86: ...This page intentionally blank...
Страница 94: ...This page is intentionally blank...
Страница 103: ......
Страница 104: ......
Страница 105: ......
Страница 106: ......
Страница 108: ...Notes...