![FleetLynx AMG1000ALx-VCM Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/fleetlynx/amg1000alx-vcm/amg1000alx-vcm_installation-manual_2303558013.webp)
AMG1000ALx-VCM Light Duty/Passenger Vehicle Kit Installation Guide
13
7.0 Confirm AMG Operation
AMG operation can be confirmed via the AMG Diagnostics Page and/or the AMG Status
Lights. The AMG Diagnostics page provides a detailed summary of AMG operation and is
accessible using an IEEE 802.11b/g enabled PC. The AMG Status Lights are located on the
side of the AMG base unit.
AMG Operation is best confirmed by viewing the AMG Diagnostics Page. In the case
where an IEEE 802.11b/g enabled PC is not available, AMG operation will have to be
confirmed by viewing AMG status lights, however, the status lights provide no information
on the Ignition Sensor connection to the AMG.
Confirming AMG Operation via the AMG Diagnostics Page
Prerequisites:
•
IEEE 802.11b/g enabled PC or laptop
•
AMG IEEE 802.11b/g radio must be in adhoc mode (factory-default)
•
AMG serial number of the unit to be checked must be known
Procedure:
Step 1
Start the truck and wait at least 90 seconds to allow the AGM unit to acheive a
steady operational state.
Step 2
Connect the PC or laptop to the AMG ad-hoc wireless network.
For Windows XP: In Control Panel->Network and Internet, click on "Connect to
a network" under the "Network and Sharing Center" heading. In the "Wireless
Network Connection" window, find the network name with the AMG serial number
"VCM-AMG-<Serial#>". Click on the name then click "connect".
Instructions for connecting to a wireless network will vary for other
operating systems.
Step 3
When prompted, enter the security key 55555.
Step 4
Using a web browser, navigate to the AMG Diagnostics page -- http://10.10.0.1
Step 5
Review the AMG Diagnostic page details as indicated in Figure 14.
Note:
The Diagnostics page does not auto-update. Refresh the page to get an updated diagnostics
view.