3200ET Remote Meter
Control Operation
Normal Operation
Remote Meter Delayed Regeneration Systems -
In Normal Operation the Time Of Day Display will alternate being viewed with the Volume Remaining Display. Water
flow through the unit is indicated by the Meter Arrow that will flash in a direct relationship to flow rate. As treated water
is used, the Volume Remaining Display will count down from a maximum value to the calculated reserve capacity. Once
this occurs, the Reserve Arrow will begin to flash as an indication that reserve capacity is being used. At the preset
Regeneration Time, a regeneration cycle will then be initiated immediately.
For Example:
125 Gallons of Water Remaining
(Timer in Service)
(No water flow)
(Volume is below reserve capacity)
For Example:
0 Gallons of Water Remaining
(Timer in Service)
(Water flowing, Meter Arrow Flashing)
(Volume is below reserve capacity)