1 - GENERAL OPERATION
3200 NXT
21
Shift button
This button allows you to move the cursor from right to left when setting the values.
Setting buttons
These buttons are used to set the time as well as the values of parameters whilst programming
the electronics.
Display during service
Some examples of display in service
- In service, single valve in timeclock mode
- In service, single valve in volume immediate or delayed mode
4 # -
S R V
1 4 : 2 4 H R
V O L U M E
8 0 0 0 L
4 # -
S R V
1 5 : 2 5 H R
R E G E N
E N
0 3
D A Y S
System type:
- 4# : single valve
- 5# : lockout system, 2 to 4 valves
- 6# : parallel system, sequential regenerations, 2 to 4 valves
- 7# : alternating system, 2 valves
- 9# : alternating system, 2 to 4 valves
Valve position in a multi-valve system, #1 being the lead valve.
Valve state:
- CHG (Change of state): shows when lower drive changes position on double
piston valves.
- INI (Initializing): shows after a power failure or a change in the programming,
the electronics will initialize for approximately 30s.
- RGQ (Regeneration queued) : shows when in a meter delayed system the
reserve capacity has been entered or a manual regeneration has been
registered.
- LCK (Lock): shows when the electronics has received the lockout signal.
- SRV (Service): shows in the service position.
- SBY (Standby): displayed when the valve is in standby.
Flow indicator: rotates when flow is going through the meter
Time of day
Operating mode:
- Remaining volume in volumetric mode
- Days remaining before a regeneration in timeclock mode
7 # 1
S R V
0 8 : 2 6 H R
V O L U M E
2 0 0 0 0 L
5
4
1
6
2
3
5
4
1.2
1
2
3
4
5
6
E
N
G
L
I
S
H