3 - PROGRAMMATION 3200 NT
3200 NT
27
E
N
G
L
I
S
H
- system #9 – multiplex meter immediate (alternated)
[ 9FI]
It allows making a system of 3 or 4 valves. Each valve has it’s own meter, only one is in standby
and the others are in service. Only one valve will be regenerating at a given time. As soon as the
softened water volume on a valve reaches zero, this unit will then go in regeneration. The valve
that was in standby goes in service then the unit that needs a regeneration goes in standby and
regeneration.
Valve position
Not visualized in simplex mode:
timeclock
[ 4tc],
meter immediate and delayed [ 4FI] [ 4Fd]
The parameter is used to do systems of 2 valves or more. Choose a lead valve [LEAD] in the
system and set the other valves to slave [ Lag]. For systems using a unique meter, it must be
connected to the lead valve.
Ex.: lead valve (first)
[LEAD]
Lag valve (second, third, forth)
[ Lag]
Remote controlled regeneration
The valve is controlled by an external device. The regeneration will start immediately after the
closure of the contact which timing is predetermined during the setting. A closure time is
requested to validate the signal before the regeneration start.
Setting values: 1 to 99 minutes
Ex. : function cancelled
[rSoF]
3 min validation
[rS -3]
Display unit
This parameter gives the choice between US display and metric.
- US display : volume in gallon, time display 2 x 12 hours, hardness in grain
[U - -1]
- metric format: volume in litre, time display 24 hours, hardness in °tH or °f
[U - -4]
System capacity
This parameter allows setting the system capacity. The electronics calculate the volume of
water that the system can condition between two regenerations.
Setting values:
- C199-C999 m
3
°tH (metric units)
- Ct1.0-Ct19 m
3
°tH (metric units)
"t" indicates a multiplication by 1000
Ex.: 450 m3°tH
[C450]
Safety coefficient
This parameter allows adapting the system capacity. The value indicated is in percentage by
which the total capacity will be reduced.
Setting values: 0 to 50 %
Ex.: reduce the system capacity of 10%
[cF10]
Inlet water hardness
This parameter allows the setting of water hardness at the input in °tH. The electronics
calculate automatically the volume of water treated based on water hardness and system
capacity.
Setting values: 2 to 199 °tH (metric units)
Ex.: 30°tH
[H- 30]
Regeneration time
This parameter allows a time setting for the regeneration. The display of this parameter is
recognisable by the 2 fixed dots between the hours and minutes.
Ex.: regeneration at 2 A.M.
[ 2:00]
1.4
1.5
1.6
1.7
1.8
1.9
1.10