SUMMARY   OF   TECHNICAL   DATA

Bandwidth

:

 

 

DC to about 1 MHz at 100 Vpp

Amplification

:

   

20 times fixed

Load

:

 

type 

resistive || capacitive

Impedance

:

 

input (each) 

1 M

Ω

 || 30

 

pF, custom values possible

 

output  

<0.1

 

Ω

 in the linear mode

Voltage

:

 

input 

nominal ±10

 

V

Current

:

 

output 

maximum 150

 

mA 

Slew Rate:

 

output 

ca 400

 

V/µs

 

 

(different adjustments available on request)

Input protection fuse

 

15 mA (Littelfuse, part number 272.015)

 

 

one spare fuse provided inside the instrument,

 

 

additional fuses available from Littelfuse

 

 

resellers or from FLC Electronics AB.

DC Level: 

 

0…+10 V, max 150 mA

Operating Ambient Temperature:

  0°C to 30°C 

Storage Temperature:

 

0°C to 60°C

Relative Humidity:

 

up to 90% (operation)

 

 

30% to 50% (storage) 

Power Requirements:

 

100/110 V or 220/230 V, 50/60 Hz

Fuse:

 

 

100/110 V: 3.15 A (slow), 

 

 

220/230 V: 2 A (slow)

Dimensions (H/W/L)

:

 

112 x 255 x 316 (mm)

Weight:

 

 

4 kg

Country of Origin:

 

Sweden

Note:

 Specifications apply to instruments operating at 23°C±5°C ambient tempera-

ture after 15 min.  warm-up  time. Due to ongoing  product development,  specifica-
tions are subject to change without notice.

WARNING

 It is not allowed to connect the 100...230V AC line power input of the 

amplifier  to DC-AC  converters  or  solid state  AC  generators with  non-sinusoidal 
output.

Data sheet revision date: 16 January, 2013

ELECTRONICS AB

WWW.FLCE.SE

Содержание A400X

Страница 1: ...BAND 200V 20x DC to ca 500 kHz 150mA FULL SCALE LOW OUTPUT IMPEDANCE HIGH SLEW RATE 0 1 400 V s ELECTRONICS AB WWW FLCE SE FLC Electronics AB Sippedalsv gen 8 S 433 31 Partille Sweden Tel 46 31 741 26...

Страница 2: ...used separately allow the unit to act as inverting or non inverting amplifier Any function or arbitrary waveform generator or any other signal source with a voltage up to 10 V can be used as an input...

Страница 3: ...e se for advice before opening the instrument case Keep input signals within 10 V range Never connect the high voltage output to the input of the instrument TROUBLESHOOTING Problem Condi on Solu on No...

Страница 4: ...preferably by email info flce se Inside the cabinet exist hazardous voltage levels and the amplifier circuit is sensitive to static discharge FLC Electronics AB recommends to monitor the output signal...

Страница 5: ...cy response without load and with 300pF and 400 pF load respectively is shown in the following diagram 1 10 100 1000 1 10 100 1000 10000 Amplitude peak to peak V Frequency kHz without load load 300pF...

Страница 6: ...max 150 mA Operating Ambient Temperature 0 C to 30 C Storage Temperature 0 C to 60 C Relative Humidity up to 90 operation 30 to 50 storage Power Requirements 100 110 V or 220 230 V 50 60 Hz Fuse 100 1...

Страница 7: ...furnish service under this warranty to repair damage resulting from attempts by personnel other than FLC Electronics representatives to install repair or service the product to repair damage resulting...

Страница 8: ...li er during power up and power down Never connect the output to the input of the ampli er The ampli er may be overheated if the output is short circuited for a long me The maximum allowable capaci ve...

Страница 9: ...d to the following standards as listed in the official Journal of the European Communities EN 50081 1 Generic Emissions EN 55022 Conducted emission interference voltage class B EN 55022 Radiated emiss...

Отзывы: