Warning : Use only the coals supplied with the fire. When replacing the
coals remove the old coals and discard them. Fit a complete set of
coals of the correct type. Do not fit additional coals or any coals
other than a genuine replacement set.
To ensure that the release of fibres from these R.C.F (Refractory Ceramic
Fibre) articles is kept to a minimum, during installation and servicing we
recommend that you use a HEPA filtered vacuum to remove any dust
accumulated in and around the appliance before and after working on the
appliance. When replacing these articles we recommend that the replaced
items are not broken up, but are sealed within heavy duty polythene bags,
clearly labelled as “RCF waste”. RCF waste is classed as a “stable”, non
reactive hazardous waste and may be disposed of at a landfill licensed to
accept such waste Protective clothing is not required when handling these
articles, but we recommend you follow the normal hygiene rules of not
smoking, eating or drinking in the work area, and always wash your hands
before eating or drinking.
FITTING THE TRIM
a)
Remove the protective tape from the trim and position onto the fixing
flange. The trim is secured with magnets.
USER REPLACEABLE PARTS
The only user replaceable parts on this fire are the fuelbed components and coals
which may be replaced as described in the above section. Replacement of any
other parts must be carried out by a competent person such as a CORGI
registered gas installer. The part numbers of the user replaceable parts are as fol-
lows, these are available from BFM Europe Ltd. who may be contacted at the
address shown below.
Fuelbed base
B-96400
Fuelbed front rails (pair)
B-96410
Replacement coal set
B-96420
Complete ceramic set (base, front rails and coals) B-96430