background image

 

Basic Service

 (See Figures 1 and 2, page 9) 

Note:  The oxy pilot must be changed annually as a condition of the guarantee. 

Remove the glass door panel and the ceramic coal matrix as previously described. 

Clean any debris and soot from the burner top. This can be done by using a soft brush 
or a vacuum cleaner. The burner mesh should be thoroughly cleaned.  

The ceramic coal matrix can be cleaned  by gently brushing with a soft brush in a 
direction away from the person and any persons nearby. This operation should be 
performed outside facing downwind. A vacuum cleaner 

must

 not be used for this 

purpose. 

Check that there is no impairment to the electrode spark or pilot burner. 

Check that the pilot flame is satisfactory. If this is not the case remove and clean (see 
instructions below). If the flame is still unsatisfactory replace the pilot burner.  

Replace the burner ceramic and glass door panel and secure with the fixing screw. 

 

To Remove the Burner/ Control Assembly

 (See Figures 1 – 6, page 9) 

Remove the rear access door and the cylinder. 

Remove the glass door panel and the ceramic coal matrix. 

Pull off the control knob. Unscrew the control lock nut (use 17mm box spanner). 

Undo and remove the two screws inside the cylinder space. These two screws are 
situated either side of the appliance between the bolts securing the front casting. 

Gently pull the control valve clear of the top casting and the lift the whole assembly 
clear. 

To replace, follow the reverse of the above locating the control valve in the top casting 
first. Check for gas leaks. Make sure that the spark lead is secured so that it cannot 
trail under the gas cylinder. 

 

To Remove the Pilot Burner

  

Remove the Burner/ Control assembly as described above. 

Unscrew the thermocouple nut from below the control valve. 

Unscrew the pilot supply tube from the pilot burner. 

Gently pull the spark lead from the electrode. 

Remove the two screws holding the pilot burner to its bracket. 

Note; Apart from cleaning the pilot burner cannot be serviced and must be replaced as 
a complete unit if faulty. When replacing, carefully coil the excess length of the 
thermocouple just under the control valve and push out of the way of the cylinder when 
the burner/ control assembly is re-installed into the stove body.  Make sure that the 
spark lead is secured so that it cannot trail under the gas cylinder.  

 

 

Содержание THURCROFT FFSC00MB

Страница 1: ...BEEN FITTED WITH A SUITABLE REGULATOR AND HOSE THE REGULATOR WILL FIT A CYLINDER WITH A 21mm VALVE THIS APPLIANCE REQUIRES A 7 kg CYLINDER OF GAS This appliance must not be used in high rise apartments basements bathrooms or bedrooms When you first light your stove you may detect a slight odour This will disappear after a few hours use THIS APPLIANCE MEETS THE REQUIREMENTS OF THE EUROPEAN GAS DIRE...

Страница 2: ...EMENTS 3 Ventilation 4 Preparing the appliance for use 4 USERS GUIDE 6 Lighting the stove 6 Moving your stove 7 Cleaning and storage 7 SERVICING MAINTENANCE 7 Installation Service Record 10 Important Note These Installation Instructions must be adhered to without exception ...

Страница 3: ...on the stove 4 Do not operate the stove close to chairs and fabrics 5 Do not move the stove when lit 6 Do not position the stove alongside a wall or near curtains etc 7 Always face the stove towards the centre of the room 8 Leakage of Gas Should a gas leak be suspected turn off the gas at the cylinder and extinguish all naked lights Contact your dealer 9 The glass door on this appliance forms a gu...

Страница 4: ...t be used A permanent vent with an effective area of 62cm2 is required together with a window that can be opened Preparing the appliance for use 1 Fitting the Ceramic Coal Matrix Loosen the slotted headed screw from beneath the glass door Lift the door upwards and remove The top of the door is located with a hidden screw in a keyhole and the door may have to be moved around to free it from the fro...

Страница 5: ...nder first turn the stove off by turning the switch downwards and then press the switch inwards towards the body of the regulator Lift to release from the cylinder Note The regulator supplied with your stove may have been exchanged for the factory fitted item and may mount in a different manner to the above Refer to the regulator instructions supplied with your appliance 7 Replace the rear access ...

Страница 6: ...ase the pilot burner may not light from the main burner and the knob will have to be released and the burners relit 3 Once the burners are both alight hold the control knob down for a further 15 seconds and then release The burners should stay alight If they do not repeat the lighting procedure only holding the knob down for longer 4 Once the burner is alight the control knob can be turned further...

Страница 7: ...ving It is easier to move with rear door and gas cylinder removed If the stove is to be transported by motor vehicle the gas cylinder should be removed as should the Ceramic Coal Matrix which should be carefully packed to avoid breakage Cleaning and storage 1 Do not attempt to clean the stove unless it is cold It should only require occasional dusting or a wipe with a damp cloth If the stove is no...

Страница 8: ... ceramic coal matrix 3 Pull off the control knob Unscrew the control lock nut use 17mm box spanner 4 Undo and remove the two screws inside the cylinder space These two screws are situated either side of the appliance between the bolts securing the front casting 5 Gently pull the control valve clear of the top casting and the lift the whole assembly clear 6 To replace follow the reverse of the abov...

Страница 9: ...ctor elbow from its carriage 4 The injector can now be removed from the elbow To Remove the Control Valve 1 Remove the Burner Control assembly as described above 2 Gently pull the spark lead from the electrode on the pilot burner 3 Unscrew the thermocouple the two 8mm supply tubes and the 4mm pilot supply tube 4 Remove the control valve FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 4 ...

Страница 10: ...Please ensure that installer completes the installation record below INSTALLATION RECORD Appliance Supplied by JJJJJJJJJ J JJ Installation Date JJJJJSerial No JJJ JJ Installed By JJJJ J No J JJJJJ Signed by Installer JJJJJJJJJJJJJJ J ...

Страница 11: ...e Date JJJJJ Signed J JJ J Comments JJJJJJJJJJJJJJJJJ JJJJJJJJJJJJJJJJJJJJJJJ JJJJJJJJJJJJJJJJJJJJJJJ RECORD OF 6th SERVICE Serviced by JJJJ No JJJJ Service Date JJJJJ Signed J JJ J Comments JJJJJJJJJJJJJJJJJ JJJJJJJJJJJJJJJJJJJJJJJJ JJJJJJJJJJJJJJJJJJJJJJJ RECORD OF 7th SERVICE Serviced by JJJJ No JJJJ Service Date JJJJJ Signed J JJ J Comments JJJJJJJJJJJJJJJJJ JJJJJJJJJJJJJJJJJJJJJJJ JJJJJJJJJJJ...

Страница 12: ...12 B 123340 Issue 1 BFM Europe Limited Trentham Lakes Stoke on Trent Staffordshire ST4 4TJ Tel 01782 339000 Fax 01782 339009 Email info bfm europe com www bfm europe com ...

Отзывы: