Flavel Richmond Plus Скачать руководство пользователя страница 6

1.3

FIREPLACE / SURROUND SUITABILITY

The fire must only be installed on a hearth it

must not be installed directly onto

carpet or other combustible floor materials.

The fire is suitable for fitting to non-combustible fire place surrounds and
proprietary fire place surrounds with a temperature rating of at least 150oc.

If a heating appliance is fitted directly against a wall without the use of a fire

surround or fire place all combustible material must be removed from behind

the trim. Soft wall coverings such as blown vinyl, wall paper etc. could be

affected by the rising hot air and scorching and/or discoloration may result.

Due consideration should be made to this when installing or decorating.

1.4

SHELF POSITION

The fire may be fitted below a combustible shelf providing there is a minimum

distance of 200mm above the top of the fire and the shelf does not project more

than 150mm. If the shelf overhangs more than 150mm the distance between the

fire and the shelf must be increased by 15mm for every 25mm of additional

overhang over 150mm.

1.5

FLUE / CHIMNEY INSPECTION

Before commencing installation, a flue or chimney should be inspected to ensure

that all the following conditions are satisfied.

1.

Check that the chimney / flue only serves one fire place and is clear of any

obstruction. Any dampers or register plates must be removed or locked in

the open position.

2.

Brick/stone built chimneys or any chimney or flue which has been used for

an appliance burning fuel other than gas must be thoroughly swept. The

base of the chimney / flue must also be thoroughly cleared of debris etc.

3.

Any under-floor air supply to the fire place must be completely sealed off.

4.

Ensure that the inside of the chimney / flue is in good condition along it’s

length and check that there is no leakage of smoke through the structure

of the chimney during and after the smoke pellet test.

5.

Using a smoke pellet, check that there is an up-draught in the

chimney / flue and that the smoke can be seen issuing from the

terminal / chimney pot outside.

There must be no leakage of smoke through the structure of

the chimney during or after the smoke pellet test and it is

important to check inside upstairs rooms adjacent to the chimney /

flue

.

6

Содержание Richmond Plus

Страница 1: ...allation Maintenance User Instructions Hand these instructions to the user after installation Model No s FOPC MN FOPC SN FOPC RN are for use on Natural Gas G20 at a supply pressure of 20 mbar in G B I...

Страница 2: ...n 4 Maintenance 4 1 Removal of the burner assembly manual control models 31 4 2 Removal of the piezo igniter manual control models 31 4 3 Removal of the control tap manual control models 32 4 4 Remova...

Страница 3: ...opreci 21100 141 MC 21100 162 SC RC Max Gross Heat Input 6 9 kW Min Gross Heat Input 4 2 kW Cold Pressure 20 0 mbar 1 0mbar Ignition Push Button Piezo MC models 1 5V Battery Generator SC models 9V Bat...

Страница 4: ...ncy Declaration The efficiency of this appliance has been measured as specified in BS 7977 1 2002 and the result is 67 The gross calorific value of the fuel has been used for this efficiency calculati...

Страница 5: ...tallation of Chimneys and flues 7 IS 813 1996 Domestic Gas Installation Republic of Ireland No purpose made additional ventilation is normally required for this appliance when installed in G B When In...

Страница 6: ...25mm of additional overhang over 150mm 1 5 FLUE CHIMNEY INSPECTION Before commencing installation a flue or chimney should be inspected to ensure that all the following conditions are satisfied 1 Chec...

Страница 7: ...The front opening of the fire place must be between 400 and 450 mm wide and between 550 and 570mm high If the opening exceeds these dimensions then a surround must be constructed from suitable non co...

Страница 8: ...figure 2 Opening Width mm Minimum Depth Required mm 400 minimum opening width 298 410 392 420 285 430 280 440 273 450 maximum opening width 269 For example if the appliance was to be fitted into a 40...

Страница 9: ...st 50mm above the floor The hearth must be fitted symmetrically about the fire opening and have a minimum width of 760mm and a minimum projection of 300mm forwards from the fire opening 1 9 SPILLAGE M...

Страница 10: ...m grommet all models 6 off 1 5V batteries RC models only 1 off 9V battery RC models only 1 off 1 5V battery SC models only 1 off Guarantee card all models 2 2 INSTALLING THE FIRE BOX Establish which t...

Страница 11: ...mage and carefully lift the fire box into the fire opening then slide it back into position Check that the fire box flange fits flush to the sealing face of the fire surround or wall with no gaps pres...

Страница 12: ...operat ing cable must be removed The control lever operating cable can be seen running across the base of the fire below the burner To release the cable unscrew the cable securing screw located in the...

Страница 13: ...assembly fixing screws at either side of the firebox and the two fixing screws at the base of the fire see figure 7 below Carefully pull the base of the burner forwards The burner can now be removed f...

Страница 14: ...from damage and carefully lift the fire box into the fire opening then slide it back into position Check that the fire box flange fits flush to the sealing face of the fire surround or wall with no ga...

Страница 15: ...oncealed pipe layouts Fig 10 Fig 11 Note Before breaking into the gas supply a tightness test should be carried out to establish that the existing pipework is sound Carefully withdraw the fire box fro...

Страница 16: ...on the protected surface of the hearth and reach into the fire opening Thread each of the cables vertically downwards through the pair of fixing eyes on the same side of the fire Thread the free end...

Страница 17: ...rews and check that the burner is correctly locked into position On slide control models refit the control cable To do this firstly locate the nipple on one end of the cable into recess in operating a...

Страница 18: ...the fire remove the manometer and refit the pressure test point screw Check the pressure test point screw for gas tightness with the appliance turned on using a suitable leak detection fluid or detec...

Страница 19: ...tightness test c Light the fire see page 28 for full details of the operating method for the fire d Check that the gas pressure is 20 0 mbar 1 0mbar 8 0 in w g 0 4 in w g e Turn off the fire remove t...

Страница 20: ...ake sure that the fuelbed base is located centrally in the fire box Ensure that the fuelbed base fit fully down onto the fuel bed support and is not lodged on the burner See figure 14 below Fig 14 b P...

Страница 21: ...in the front ceramic rail as a guide for placement see figure 16 below Fig 16 d Select four of the large coals and arrange behind the front row of coals ensuring that flame paths as indicated below a...

Страница 22: ...ear of the fuelbed using the ribs in the rear of the fuelbed as a guide for placement See figure 18 below Fig 18 f Select the four remaining large coals and position to fill the gaps at each end of th...

Страница 23: ...the fire before and after working on the fire When replacing these articles we recommend that the replaced items are not broken up but are sealed within a heavy duty poly thene bag clearly labelled a...

Страница 24: ...in the ashpan cover so that the infrared eye is flush with the front edge of the ashpan cover as shown below in figure 21 Check the operation of the handset as detailed in section 3 10 and adjust the...

Страница 25: ...t cradle at the bottom R H side of the firebox burner assembly c The wire and connecting plug from the battery pack should then be connected into the supply wire running from the control board See fig...

Страница 26: ...n the control knob is released repeat the lighting sequence d Turn the control knob in the anti clockwise direction to the high position and the main burner will light e Turn the control knob clockwis...

Страница 27: ...ouple to heat up before releasing the lever apply one firm downwards push to ensure that the f s d valve is fully latched if the pilot goes out when the control lever is released repeat the lighting s...

Страница 28: ...burner The ignition cycle will take approximately 20 seconds c To reduce the level of heat input on the fire point the handset at the fire and press the small flame button An audible beep will be hea...

Страница 29: ...occurring and the flue restrictor baffle has been fitted it should be removed and the test repeated after the fire has cooled See figure 25 below for details of how to remove and re fit the restrictor...

Страница 30: ...n disappear At this stage any minor adjustments to the coals should be made using suitable long handled tongs and taking care not to damage the coals Finally hand the Installation and Maintenance Inst...

Страница 31: ...r out of the way and put them in a safe location Remove the loose coals from the fuel bed and front ceramic rail Remove the front ceramic from the rail Unscrew the two pozi driv fixing screws which se...

Страница 32: ...ble to replace the thermocouple separately because the thermocouple position is factory set to a tight tolerance Any replacement of parts on the pilot requires a complete new pilot assembly 4 4 1 Remo...

Страница 33: ...osition Secure using the two screws into the side frame of the firebox and two screws into the base It is now necessary to refit the operating arm front section to the rear section reverse of procedur...

Страница 34: ...and remove the two pozi drive screws which secure the pilot assembly to the burner Remove the pilot 4 8 4 Re assemble in reverse order and carry out a gas tightness test 4 9 Replacing the Control Cab...

Страница 35: ...n the locking bush and tighten the screw sufficiently to retain the cable but still allowing it to slide for adjustment 4 9 6 It is now necessary to correctly tension the operating cable To do this fi...

Страница 36: ...e PCB assembly Push the base of the control panel fully into the fire and secure with the four screws Refit the gas supply pipe and carry out a gas tightness test Refit the burner heat shield then ref...

Страница 37: ...ioned 4 13 Replacing the Batteries Within the Firebox 4 13 1 Remove the fender and ashpan assembly The battery holder is located on the right hand side of the appliance 4 13 2 Remove the battery pack...

Страница 38: ...such as a GAS SAFE registered gas installer The part numbers of the replaceable parts are as follows these are available from BFM Europe who may be contacted at the address shown on the rear cover Fu...

Страница 39: ...s Authority of Ireland Any purpose made ventilation should be checked periodically to ensure that it is free from obstruction If the chimney or flue has been previously used by appliances burning fuel...

Страница 40: ...s appliance is serviced at least once a year by a GAS SAFE registered installer and that during the service the fire is removed from the fire opening and the chimney or flue visually checked for falle...

Страница 41: ...unlikely event of a failure of the igniter the fire can be lit as follows Depress the control knob and turn anti clockwise to the position marked pilot Hold in the control knob for a few seconds to al...

Страница 42: ...n the unlikely event of a failure of the igniter firstly check the operation of the 1 5V battery and if necessary replace with a AA size alkaline battery It is important that only an alkaline battery...

Страница 43: ...nce the fire is allowed to warm up for a few minutes with the input set to high b To reduce the level of heat input on the fire point the handset at the fire and press the small flame button once An a...

Страница 44: ...s out for any reason or is turned off and it is necessary to re light the fire it is important to allow the fire to cool for 3 minutes before attempting to re light it High Large Flame Low Small Flame...

Страница 45: ...off switch on the control panel b To turn the product off firstly remove the ashpan from the fire c Press and hold the emergency shut off switch until the fire shuts down The process may take up to si...

Страница 46: ...cated on the right hand side side of the burner unit at the bottom c Unscrew the retaining cap remove and replace the battery then replace the retaining cap 5 8 SPILLAGE MONITORING SYSTEM All models r...

Страница 47: ...surface The fender that was supplied with the fire is laquered to protect the finish and therefore must only be cleaned using a clean damp cloth Abrasive cleaners chemical cleaning agents or any type...

Страница 48: ...fuelbed base is located centrally in the fire box Ensure that the fuelbed base fit fully down onto the fuel bed support and is not lodged on the burner See figure 4 below Fig 4 b Position the two halv...

Страница 49: ...s in the front ceramic rail as a guide for placement See figure 6 below Fig 6 d Select four of the large coals and arrange behind the front row of coals ensuring that flame paths as indicated below a...

Страница 50: ...rear of the fuelbed using the ribs in the rear of the fuelbed as a guide for placement See figure 8 below Fig 8 f Select the four remaining large coals and position to fill the gaps at each end of the...

Страница 51: ...king on the fire When replacing these articles we recommend that the replaced items are not broken up but are sealed within a heavy duty poly thene bag clearly labelled as RCF waste This is not classi...

Страница 52: ...accuracy of illustrations and descriptions contained in this book cannot be guaranteed Part No B 149180 Issue 2 BFM Europe Ltd Trentham Lakes Stoke on Trent Staffordshire ST4 4TJ www bfm europe com Te...

Отзывы: