Flavel REGENT L.F.E. Скачать руководство пользователя страница 26

ABOUT YOUR NEW FLAVEL REGENT LFE GAS FIRE

The Flavel Regent L.F.E. gas fire incorporates a unique and highly developed

fuelbed which gives good flame aeshetics whilst maintaining reasonable running

costs.

Please take the time to fully read these instructions as you will then be able to

obtain the most effective and safe operation of your fire.

IMPORTANT SAFETY INFORMATION

WARNING

This appliance has a naked flame and as with all heating appliances a

fireguard should be used for the protection of children, the elderly and

infirm. Fireguards should conform to B.S. 8423 : 2002 should be fitted.

(Fireguards for use with gas heating appliances).

It is important that this appliance is serviced at least once a year by a

registered gas installer and that during the service the fire is removed from the fire

opening and the chimney or flue visually checked for fallen debris or blockages

which must be removed. The chimney should also be checked to ensure

clearance of flue products. We recommend that during the annual service,

replacement of the Oxypilot is carried out.

After installation or during servicing

a spillage test must always be carried out.

Rubbish of any type must NEVER be thrown onto the ceramics, this could affect

safe operation and damage the fire.

Any debris or deposits should be removed from the fuel-bed from time to time.

This may be carried out by referring to the cleaning section as described later in

this book.

Only the correct type of fuelbed ceramics must be used and only complete and

genuine replacement sets must be sourced from BFM Europe Ltd.

Always keep furniture and combustible materials well clear of the fire and never

dry clothing or items either on or near to the fire. Never use aerosols or

flammable cleaning products near to the fire when it is in use.

The ceramic fuel-bed remains hot for a considerable period after use and

sufficient time should be allowed for the fire to cool before cleaning etc.

The fire must only be operated with the dress guard supplied with the fire

3

Содержание REGENT L.F.E.

Страница 1: ...IVE FUEL EFFECT CONVECTOR GAS FIRE Installation Maintenance User Instructions Hand these instructions to the user Model No s FRLCP0RN FRLCN0RN are for use on Natural Gas G20 at a supply pressure of 20...

Страница 2: ...t Flue Installations 8 1 9 Hearth Fitting 8 1 10 Spillage Monitoring System 8 Section 2 2 1 Packing Check List 9 2 2 Installation of Fire 9 10 2 3 Gas Connection 11 2 4 Gas Tightness 12 Section 3 3 1...

Страница 3: ...feet fitted 680mm Depth 255mm Height to top of the flue spigot 525mm with feet fitted Gas Connection 8mm compression Supplied with fire Efficiency Declaration The efficiency of this appliance has been...

Страница 4: ...mneys Flues 5 B S 1251 Open Fireplace Components 6 B S 715 Metal Flue pipes for Gas Appliances 7 B S 1289 Clay Flue blocks and Terminals 8 B S 7566 Installation of factory made Chimneys Ventilation Re...

Страница 5: ...e than 150 mm If the shelf overhangs more than 150 mm the distance between the fire and the shelf must be increased by 25 mm for every 25 mm of additional overhang over 150 mm 1 5 SIDE CLEARANCE A min...

Страница 6: ...during or after the smoke pellet test and it is important to check inside upstairs rooms adjacent to the chimney flue Check the chimney pot terminal and general condition of the chimney brickwork or...

Страница 7: ...may be fitted if necessary providing that a minimum clearance 50mm between its open end and nearest obstruction is always maintained Fig 1 Chimney Catchment Space 1 8 2 Fitting to Pre Fabricated twin...

Страница 8: ...oved when installing directly onto a hearth The hearth material must be a minimum thickness of 13 mm with the top surface at least 50 mm above the floor level The hearth must be fitted symmetrically a...

Страница 9: ...s Pack 1 off Fuelbed Pack 1 off Remote Handset 1 off Battery pack 2 2 INSTALLATION OF FIRE 2 2 1 Preparation a Remove the dress guard by springing the location wires out at the bottom and lifting away...

Страница 10: ...ke If there is a definite flow into the opening then proceed with the installation If there is not a definite flow into the opening pre heat the chimney for about two minutes and retest for flow If th...

Страница 11: ...nlet pipework to isolate the appliance for servicing and repair purposes Before making the final gas connection thoroughly purge the gas supply pipe work to remove all foreign matter otherwise serious...

Страница 12: ...tion 3 1 and carry out a gas tightness test c Check that the gas pressure is 20 0 mbar 1 0 mbar 8 0 in w g 0 4 in w g d Turn off the fire remove the manometer and refit the pressure test point screw C...

Страница 13: ...bezel clear Unscrew the black painted shield which is held in place by 2 off screws 1 at the L H S and 1 at the R H S Locate the battery pack in the support cradle at the bottom R H side of the fire...

Страница 14: ...and infrared eye attached to the flying lead as supplied from the factory Fig 7 b Remove the backing paper from the self adhesive pad and position the infrared eye in the corner of the ashpan cover s...

Страница 15: ...s can now be released After a few seconds an audible clicking can be heard and then the fire will light the pilot and then light the main burner The ignition cycle will take approximately 20 seconds c...

Страница 16: ...nded that the smoke match is fitted into an approved smoke match holder when checking for clearance of combustion products Fig 10 e If the smoke is not drawn into the flue aperture remove the efficein...

Страница 17: ...l when the bezel and heat shield are removed e Inform the User the fire should be serviced annually for continued safe operation f Hand this instruction booklet to the customer IF A REPLACEMENT FUELBE...

Страница 18: ...d be replaced with a genuine replacement set After any servicing work a gas tightness test must always be carried out 4 1 GENERAL ACCESS FOR SERVICING 4 1 1 TO REMOVE THE UPPER CANOPY a Prepare work a...

Страница 19: ...IRE a Disconnect the appliance from the gas supply Remove the front panel by unscrewing the retaining nuts below the front panel as shown in Fig 9 below Fig 9 b Remove the front bezel by unscrewing th...

Страница 20: ...retaining holes and lift forward to remove as shown below in Fig 11 Fig 11 d Remove the four burner retaining screws disconnect the pilot assy and lift the burner clear 20 Front bezel retaining screw...

Страница 21: ...e this appliance is fitted with an atmosphere sensing ODS pilot it is not possible to replace the thermocouple separately because the thermocouple position is factory set to a tight tolerance Any repl...

Страница 22: ...e b Remove the coals and fuel bed matrix Pull the fire forwards and tilt fire onto its back to allow access to control board underneath situated in centre Remove the black painted heat shield by remov...

Страница 23: ...st spares stockists whose details can be found on our web site www bfm europe com in the stockist section Fuelbed Set B 66010 Remote Handset B 63600 Injector B 66390 EDB Control Board B 106800 Gas val...

Страница 24: ...E User Instructions This section of the instructions should be read by the user before operating the appliance and retained for future reference Model No s FRLCP0RN FRLCN0RN are for use on Natural Gas...

Страница 25: ...rpose made additional ventilation is normally required for this appliance when installed in G B When installed I E please consult document I S 813 1996 Domestic Gas Installation which is issued by the...

Страница 26: ...e chimney should also be checked to ensure clearance of flue products We recommend that during the annual service replacement of the Oxypilot is carried out After installation or during servicing a sp...

Страница 27: ...can now be released After a few seconds an audible clicking can be heard and then the fire will light the pilot and then light the main burner The ignition cycle will take approximately 20 seconds c T...

Страница 28: ...omplete see Fig 2 below c When the fire has shut down release the emergency shut off switch d The appliance will now remain in the off position until activated by the remote handset Fig 2 REPLACING TH...

Страница 29: ...ING WARNING Before attempting any cleaning operation ensure that the fire has been allowed to fully cool CLEANING THE FUELBED CERAMICS We do not recommend regular cleaning of the fuelbed ceramics as t...

Страница 30: ...out at the top and lifting away See fig 2 below Clean the dress guard or reflector by wiping with a damp cloth and polish with a dry duster DO NOT USE ABRASIVE CLEANERS CLEANING THE CASE Dusting is no...

Страница 31: ...ort bracket as indicated below in Fig 3 Fig 3 b Fit the front section of the fuelbed to the combustion chamber locating behind the front casting as shown overpage in Fig 4 Fig 4 c Refit the dress guar...

Страница 32: ...the exact accuracy of descriptions and illustrations cannot be guaranteed Part no B 120510 Issue 3 BFM Europe Ltd Trentham Lakes Stoke on Trent Staffordshire ST4 4TJ www bfm europe com Telephone Gene...

Отзывы: