4.3
REMOVING THE REMOTE GAS VALVE FROM THE FIRE
a)
Disconnect the appliance from the gas supply.
b)
Remove the upper canopy as shown in section 4.1
c)
Remove the left hand side panel, by unscrewing the rear panel fixing
screws, then the base panel retaining screw, as shown below in fig. 12
Fig. 12
c)
Disconnect the pipes to the remote gas control control valve and
disconnect the thermocouple connection.
d)
Replace in reverse order and carry out a gas tightness test.
4.4
REMOVING THE ODS- PILOT ASSEMBLY
Note : Because this appliance is fitted with an atmosphere sensing ODS-pilot
it is not possible to replace the thermocouple separately, because the
thermocouple position is factory set to a tight tolerance. Any replacement of
parts on the pilot requires a complete new pilot assembly.
a)
Remove the front panel and front bezel as described in section 4.2
Remove the black painted heat shield by removing the L/H/S & R/H/S
retaining screws.
b)
Unscrew the pilot fixing screws. These can be accessed from the front
of the appliance with the front panel and bezel removed.
c)
Remove the thermocouple as described in section 4.3. (d)
Rear side panel
retaining screws
Front retaining
screw on the
underside of
the leg support
bracket
21