MAINTENANCE INSTRUCTIONS
Servicing Notes
Servicing should be carried out annually by a competent person such as a
GAS SAFE registered engineer. The service should include visually checking
the chimney and fire opening for accumulations of debris and a smoke test to
check for positive up-draught in the chimney. In addition the oxy-pilot must
be changed as a condition of the guarantee. The condition of the ceramic
plaques should be checked and if necessary the whole set should be replaced
with a genuine replacement set. After any servicing work a gas tightness
check must always be carried out.
Ensure before any servicing work is commenced that the applinace is
isolated from the electrical supply.
4.1
GENERAL ACCESS FOR SERVICING
4.1.1
TO REMOVE THE UPPER CANOPY
a)
Prepare work area (lay down dustsheets etc.), Disconnect the appliance
from the gas supply.
b)
Remove the four canopy rear fixing screws, and the two fixing screws
that are located on the underside of the canopy (see fig 6 & 7
respec tively)
c)
Remove the radiants and move to a safe place
d)
Re-assemble in the reverse order.
Fig. 6 Removing the four canopy rear fixing screws
15