INSTALLATION INFORMATION

CONDITIONS OF INSTALLATION

It is the law that all gas appliances are installed only by a competent (e.g. CORGI

Registered) Installer, in G.B. in accordance with the installation instructions and

the Gas Safety (Installation and Use) Regulations 1998. Failure to install

appliances correctly could lead to prosecution. It is in your own interest and that

of safety to comply with the law.

The fire may be fitted below a combustible shelf provided that the shelf is at least

100mm above the top of the appliance and the depth of the shelf does not exceed

150mm.

The fire may be installed below combustible shelves which exceed 150mm deep

providing that the clearance above the fire is increased by 15mm for each 25mm

of additional overhang in excess of 150mm.

No purpose made additional ventilation is normally required for this

appliance when installed in G.B. When installed I.E. please consult

document I.S. 813 : 1996 Domestic Gas Installation which is issued by the

National Standards Authority of Ireland. Any purpose made ventilation

should be checked periodically to ensure that it is free from obstruction.

If the chimney or flue has been previously used by appliances burning fuels other

than gas they must be swept prior to the installation of this fire.

If this appliance is fitted directly on to a wall without the use of a fireplace or

surround, soft wall coverings such as wallpaper, blown vinyl etc. could be affected

by the heat and hot air and may discolour or scorch. This should be considered

when installing or decorating.

The Model number of this appliance is as stated on the rating plate affixed to the

inner rear panel of the fire and the appliance is manufactured by:-

BFM Europe Ltd

Trentham Lakes

Stoke on Trent

ST4 4TJ

2

Содержание Firenza FFIRR0MN

Страница 1: ...RADIANT CONVECTOR GAS FIRE Installation and Maintenance Instructions Hand these instructions to the user Model No s FFIRZ1MN FFIRR0MN are for use on Natural Gas G20 at a supply pressure of 20 mbar in...

Страница 2: ...ons 8 1 9 Hearth Fitting 8 1 10 Wall Mounting 8 1 11 Spillage Monitoring System 8 Section 2 2 1 Packing Check List 9 2 2 Installation of Fire 9 10 2 3 Hearth Fixing 11 2 4 Wall Mounting 11 2 5 Gas Con...

Страница 3: ...n Gross Heat Input 1 8 kW Cold Pressure 20 0 1 0 mbar 8 0 0 4 in w g Ignition Rotary piezo integral to gas valve Electrode Spark Gap 4 0 mm Weight Packed 15kg Firebox Dimensions with case fitted Width...

Страница 4: ...imneys Flues 5 B S 1251 Open Fireplace Components 6 B S 715 Metal Flue pipes for Gas Appliances 7 B S 1289 Clay Flue blocks and Terminals 8 B S 7566 Installation of factory made Chimneys Ventilation R...

Страница 5: ...es not project more than 150 mm If the shelf overhangs more than 150 mm the distance between the fire and the shelf must be increased by 25 mm for every 25 mm of additional overhang over 150 mm 1 5 SI...

Страница 6: ...during or after the smoke pellet test and it is important to check inside upstairs rooms adjacent to the chimney flue Check the chimney pot terminal and general condition of the chimney brickwork or...

Страница 7: ...gth of 125mm may be fitted if necessary providing that a minimum clearance 50mm between its open end and nearest obstruction is always maintained Fig 1 Chimney Catchment Space 1 8 2 Fitting to Pre Fab...

Страница 8: ...least 50 mm above the floor level The hearth must be fitted symmetrically about the fire opening and have a minimum width of 760 mm and a minimum projection of 300 mm forwards from the fire opening 1...

Страница 9: ...guard by springing the location wires out at the top and lifting away See Fig 2 Take care not to scratch the case Fig 2 Remove the Dress Guard b Remove the two case fixing screws located underneath t...

Страница 10: ...observe the smoke If there is a definite flow into the opening then proceed with the instal lation If there is not a definite flow into the opening pre heat the chimney for about two minutes and rete...

Страница 11: ...emove the lower screws and screw in the upper ones to leave a 7 to 8mm gap under the heads Remove the fire feet Hang the fire on the upper screws remove the lower screws and tighten all four screws 2...

Страница 12: ...first into the radiant canopy and then lowering and seating the base of the radiants into the radiant support channel b Refit the dress guard 3 2 Lighting the Appliance a Light the pilot by depressing...

Страница 13: ...xercise after a further 5 10 minutes Note It is recommended that the smoke match is fitted into an approved smoke match holder when checking for clearance of combustion products Fig 5 e If the smoke i...

Страница 14: ...me a slight odour may be noticed this is due to the newness of the fire and will soon disappear 3 4 Final Check a Refit the Dress guard if it has not already been re fitted b Recheck the operation of...

Страница 15: ...ramic plaques should be checked and if necessary the whole set should be replaced with a genuine replacement set After any servicing work a gas tightness test must always be carried out 4 1 GENERAL AC...

Страница 16: ...G THE BURNER ASSEMBLY FROM THE FIRE a Remove the case as described in section 4 1 1 Disconnect the pilot and remove Remove the four burner fixing screws as shown below in Fig 8 and slide the burner of...

Страница 17: ...se as described in section 4 11 c Disconnect the main pipe inlet pipe pilot pipe from the valve then remove the push fit thermocouple and ignition lead as shown below in fig 9 Fig 9 d Remove the contr...

Страница 18: ...of parts on the pilot requires a complete new pilot assembly a Remove the front panel and front bezel as described in section 4 2 b Unscrew the pilot fixing screws These can be accessed from the fron...

Страница 19: ...available from specialist spares stockists whose details can be found on our web site www cfm europe com in the stockist section Ceramic Plaques Set FC P079649 Gas valve B 63250 ODS Pilot Assy NG B 6...

Страница 20: ...Instructions This section of the instructions should be read by the user before operating the appliance and retained for future reference Model No s FFIRZ1MN FFIRR0MN are for use on Natural Gas G20 at...

Страница 21: ...purpose made additional ventilation is normally required for this appliance when installed in G B When installed I E please consult document I S 813 1996 Domestic Gas Installation which is issued by...

Страница 22: ...hich must be removed The chimney should also be checked to ensure clearance of flue products We recommend that during the annual service replacement of the Oxypilot is carried out After installation o...

Страница 23: ...affected by a partially or fully blocked flue If this system operates the fire will go out If this occurs leave the fire for at least three minutes then follow the lighting procedure as described in...

Страница 24: ...down for 10 seconds c If the pilot fails to light repeat the ignition sequence and hold in the control knob for slightly longer d When the pilot has lit release the control knob from the depressed po...

Страница 25: ...all soot deposits that accumulate on the ceramics can easily be cleaned Carefully remove the ceramics and brush gently with a soft brush To remove the ceramic remove the dress guard as shown in fig 2...

Страница 26: ......

Страница 27: ......

Страница 28: ...st the support bracket as shown Fig 4 Due to our policy of continual improvement and development the exact accuracy of descriptions and illustrations cannot be guaranteed Part No B 66320 Issue 5 BFM E...

Отзывы: