SECTION 1
INFORMATION AND REQUIREMENTS
1.0
APPLIANCE INFORMATION
Model
FSRC**MN & FSRP**MN
** denotes fascia variant of product
Gas Type
G20
Main injector (1 off)
Size 440
Burner Type
Aeromatic Self Vitiating Tubular Burner
Max. Gross Heat Input :
6.5 kW
Min. Gross Heat Input &
Ignition Rate :
2.2 kW
Cold Pressure :
20.0 +/-1.0 mbar
Ignition :
Push-button Piezo
Electrode Spark Gap
4.0mm
Packed Weight (All models)
13.0 kg
Fire box Dimensions (with trim fitted)
Width :
(with trim fitted)
560mm
Height : (with trim fitted)
690mm
Depth :
(trim only)
50mm
Depth :
(firebox only)
125mm
Gas Connection :
8mm Compression
(Supplied with fire)
Appliance Efficiency Declaration
The efficiency of this appliance has been measured as specified in
BS 7977-1 : 2002 and the result is 51%.
The gross calorific value of the fuel has been used for this efficiency
calculation.
The test data from which it has been calculated has been certified by
Advantica. The efficiency value may be used in the UK Government’s
Standard Assessment Procedure (SAP) for energy rating of dwellings.
3