Flavel Finesse FSRC**MN Скачать руководство пользователя страница 20

The exact position and fit of the coals may be finely adjusted to give the best

appearance.

Warning : Use only the coal set supplied with the fire. When replacing the

coals remove the old coals and discard them. Fit a complete set of coals of

the correct type. Do not fit additional coals or any coals other than a

genuine replacement set.

This appliance uses fuel effect pieces containing Refractory Ceramic Fibres

(R.C.F.), which are man-made vitreous silicate fibres. Excessive exposure to

these materials may cause temporary irritation to eyes, skin and respiratory

tract. Consequently, it makes sense to take care when handling these

articles to ensure that the release of dust is kept to a minimum. To ensure

that the release of fibres from these R.C.F. articles is kept to a minimum,

during installation & servicing we recommend that you use a HEPA filtered

vacuum to remove any dust and soot accumulated in and around the fire,

before and after working on the fire. When replacing these articles we

recommend that the replaced items are not broken up, but are sealed within

a heavy duty polythene bag, clearly labelled as “RCF waste”. This is not

classified as “hazardous waste” and may be disposed of at a tipping site

licensed for the disposal of industrial waste. Protective clothing is not

required when handling these arrticles, but we do recommend you follow the

normal hygiene rules of not smoking, eating or drinking in the work area,

and always wash your hands before eating or drinking.

This appliance does not contain any component manufactured from

asbestos or asbestos related products.

3.2

ASSEMBLING THE FUEL-BED - Pebble Fuelbed Model

a)

Place the fuelbed base centrally on to the fuelbed support and push

fully backwards to the rear face of the fibre boards

Make sure that the

fuelbed base is located centrally in the fire box

. See Fig. 15 below

Fig. 15

20

Содержание Finesse FSRC**MN

Страница 1: ...GAS FIRE Installation Maintenance User Instructions Hand these instructions to the user Model No s FSRC MN FSRP MN are for use on Natural Gas G20 at a supply pressure of 20 mbar in G B I E denotes fa...

Страница 2: ...essure 17 Section 3 Assembling Fuel Bed and Commissioning 3 1 Assembling the ceramics and fuel bed Coal models 18 19 3 2 Assembling the ceramics and fuelbed Pebble models 20 23 3 3 Fitting the Fascia...

Страница 3: ...Dimensions with trim fitted Width with trim fitted 560mm Height with trim fitted 690mm Depth trim only 50mm Depth firebox only 125mm Gas Connection 8mm Compression Supplied with fire Appliance Effici...

Страница 4: ...s Concrete Flue Blocks 8 I S 813 1996 Domestic Gas Installation Republic of Ireland No purpose made additional ventilation is normally required for this appliance when installed in G B When Installing...

Страница 5: ...15mm for every 25mm of additional overhang over 150mm 1 5 FLUE CHIMNEY INSPECTION Before commencing installation a flue or chimney should be inspected to ensure that all the following conditions are s...

Страница 6: ...nce 1 6 FIRE PLACE OPENING AND CHIMNEY CATCHMENT SPACE The front opening of the fire place must be between 330 and 440 mm wide and between 550 and 575mm high If the opening exceeds these dimensions th...

Страница 7: ...mm Minimum Depth Required mm 330 minimum opening width 152 340 149 350 146 360 144 370 142 380 139 390 137 400 135 410 132 420 130 430 127 440 maximum opening width 125 For example if the appliance w...

Страница 8: ...h the fire surround may be packed away from the wall using suitable non combustible board providing the installation is correctly sealed If in doubt about the suitability of the fire contact BFM Europ...

Страница 9: ...oxygen sensing burner This is designed to shut the fire off in the event of a partial or complete blockage of the flue causing a build up of combustion products in the room in which the fire is opera...

Страница 10: ...ending to install the fire in to 225 x 225mm 9 inch x 9 inch brick built chimneys 175mm 7 inch diameter lined brick or stone flue or insulated pre fabricated metal flue box to B S 715 When installing...

Страница 11: ...below If installing into a conventional opening with a hearth panel create an opening as shown in Fig 4 below Fig 3 Hole in the Wall Installations Fig 4 Conventional Installations 11 Minmum 250mm Min...

Страница 12: ...ckets from the back of the firebox allowing the burner to be removed See fig 6 below Fig 6 c Ensure that the hearth is protected from damage and carefully lift the fire box into the fire opening then...

Страница 13: ...n to the appliance should be made to the isolating inlet elbow using 8mm rigid tubing There must be no soldered joints within the firebox See fig 7a 7b below for suggested concealed pipe layouts Fig 7...

Страница 14: ...and a blunt chisel remove the inlet aperture selected and then seal with the grommet supplied To provide access for the gas supply pipe cut the grommet with a sharp knife Failure to seal the inlet ap...

Страница 15: ...ing the screws and rawlplugs provided To fit using the preferred cable method proceed as follows e Mark out and drill 4 off No 14 7mm holes in the back face of the fire opening in the positions shown...

Страница 16: ...ut i Fit a screwed nipple on to each of the cables and pull hand tight up against the tensioning screw then secure each nipple with a flat bladed screwdriver See fig 10 below Fig 10 j Evenly tighten t...

Страница 17: ...plugs provided Below fig 11 is a diagram to indicate the hole centre positions available on the firebox to facilitate the screw fixing to the fireplace surround Fig 11 2 4 GAS TIGHTNESS AND INLET PRES...

Страница 18: ...ck the pressure test point screw for gas tightness with the appliance turned on using a suitable leak detection fluid or detector SECTION 3 ASSEMBLING FUEL BED AND COMMISSIONING 3 1 ASSEMBLING THE FUE...

Страница 19: ...row of coals ensuring that the flame paths as indicated are not interupted See Fig 13 below Fig 13 c Fit the remaining three coals onto the ribs in the fuelbed as shown below ensuring that the rear fl...

Страница 20: ...you use a HEPA filtered vacuum to remove any dust and soot accumulated in and around the fire before and after working on the fire When replacing these articles we recommend that the replaced items a...

Страница 21: ...uring that the flame paths as indicated are not interupted See Fig 16 below Fig 16 c Fit the three small pebbles onto the ribs in the fuelbed as shown below ensuring that the rear flame paths as indic...

Страница 22: ...minimum To ensure that the release of fibres from these R C F articles is kept to a minimum during installation servicing we recommend that you use a HEPA filtered vacuum to remove any dust and soot a...

Страница 23: ...at the fuelbed is located behind the locating tabs as shown below in Fig 18a not on top of the locating tabs as shown in Fig 18b Fig 18a Shows correct location of fuelbed Fig 18b Shows incorrect locat...

Страница 24: ...e to press the igniter button until ignition occurs Continue to hold the control knob for a minimum of 20 seconds to allow the thermocouple to heat up if the burner goes out when the control knob is r...

Страница 25: ...If spillage persists the flue is not functioning correctly and a fault exists If after investigation the fault cannot be traced and rectified the fire must be disconnected from the gas supply and expe...

Страница 26: ...c 4 1 2 Remove the fascia and put it in a safe location Remove the loose coals or pebbles from the fuel bed Remove the fuelbed matrix 4 1 3 Isolate the gas supply and remove the inlet pipe from the ap...

Страница 27: ...hermocouple 4 4 1 Remove the burner assembly as in section 4 1 4 4 2 Remove the push in thermocouple from the end of the control tap and and remove the thermocouple retaining nut from the mounting bra...

Страница 28: ...ess of 150mm No purpose made additional ventilation is normally required for this appliance when installed in G B When installed I E please consult document I S 813 1996 Domestic Gas Installation whic...

Страница 29: ...ced at least once a year by a CORGI registered gas installer and that during the service the fire is removed from the fire opening and the chimney or flue visually checked for fallen debris or blockag...

Страница 30: ...and turn anti clockwise to the position marked ignition rate Hold in the control knob for a few seconds to allow the gas to reach the burner Insert the tip of a lit taper in below the fuelbed ceramic...

Страница 31: ...lacement set and the fire must never be run with the wrong number or damaged coals pebbles The fuel bed must be carefully re assembled as stated in section 5 4 5 5 dependent upon model chosen pages 31...

Страница 32: ...fully backwards to the rear face of the fibre boards Make sure that the fuelbed base is located centrally in the fire box See Fig 20 below Fig 20 b Position the front row of four loose coals along be...

Страница 33: ...when handling these articles to ensure that the release of dust is kept to a minimum To ensure that the release of fibres from these R C F articles is kept to a minimum during installation servicing w...

Страница 34: ...ar face of the fibre boards Make sure that the fuelbed base is located centrally in the fire box See Fig 23 below Fig 23 b Position the front row of four large loose pebbles along behind the first row...

Страница 35: ...care when handling these articles to ensure that the release of dust is kept to a minimum To ensure that the release of fibres from these R C F articles is kept to a minimum during installation servi...

Страница 36: ...re that the fuelbed is located behind the locating tabs as shown below in Fig 26a not on top of the locating tabs as shown in Fig 26b Fig 26a Shows correct location of fuelbed Fig 26b Shows incorrect...

Страница 37: ......

Страница 38: ......

Страница 39: ......

Страница 40: ...t the exact accuracy of descriptions and illustrations cannot be guaranteed Part no B 99350 Issue 5 BFM Europe Ltd Trentham Lakes Stoke on Trent Staffordshire ST4 4TJ www bfm europe com Telephone Gene...

Отзывы: