2.3

PREPARATION OF THE FLUE HOLE

a)

Mark the position of the centre of the flue on the inner wall.

b)

Cut hole for outer flue pipe.  There are two possible methods to achieve
this, either core drill or via hammer and chisel.

c)

To core drill, proceed as follows :- 

Drill a pilot hole through the wall, in position as specified in figure 4.

Using a 6” core drill, drill the flue hole. 

To Hammer and chisel, proceed as follows :-

Mark the position of the centre of the flue pipe as specified in figure 4.

Mark the position of the hole around this point.

Chisel out the area as marked on the wall.

We then recommend that a cardboard cylinder is placed around the flue pipe and
inserted in the chiselled out hole whilst making good.

NOTE :-

If the appliance is to be installed into a building under 

construction, it is recommended that a non-corrosive metal tube of 6” 
diameter be inserted into the position of the hole as specified on page 7.

Prior to installing the combustion chamber and flue pipe assembly, ensure the 
decorative side trims are secured with the screws as shown below in Fig. 5 a

Fig. 5a

8

Decorative Side
Trims screw to side
panel of fire with
screws provided

Содержание Emberglow FEBC00MN

Страница 1: ...Tel 0161 620 6677 Emberglow COAL EFFECT BALANCED FLUE GAS FIRE Installation and Maintenance Instructions Hand these instructions to the user Model No s FEBC00MN is for use on Natural Gas G20 at a supp...

Страница 2: ...l 11 12 2 7 Fitting the terminal guard 12 2 8 Removal refitting of the glass frame 13 Section 3 Assembling Fuel Bed and Commissioning 3 1 Fitting the fuel bed 14 3 2 Lighting the appliance 15 16 3 3 F...

Страница 3: ...ize 360 Pilot Type S I T 140 Series NG size 27 Max Gross Heat Input 5 25 kW Min Gross Heat Input 2 05 kW Gas Rate 0 470 m3 hr High 0 190 m3 hr Low Cold Pressure 20 0 1 0 mbar 8 0 0 4 in w g Ignition I...

Страница 4: ...ber framed building please consult document IGE UP 7 issued by the Institute of Gas Engineers In Republic of Ireland No purpose made additional ventilation is normally required for this appliance when...

Страница 5: ...12in opening window B Above an opening air brick 300mm 12in opening window C Horizontally to an opening air brick opening window etc D Below gutters soil pipes or drain pipes 300mm 12in E Below eaves...

Страница 6: ...or other floor coverings over it The hearth must be fitted symmetrically about the fire opening and have a minimum width of 760 mm and a minimum projection of 350 mm forwards from the fire opening SE...

Страница 7: ...does not distort when installed Ensure that the floor surface onto which the appliance is mounted onto is flat and the hearth size conforms to the requirements of section 1 5 on page 6 The minimum hei...

Страница 8: ...flue pipe as specified in figure 4 Mark the position of the hole around this point Chisel out the area as marked on the wall We then recommend that a cardboard cylinder is placed around the flue pipe...

Страница 9: ...minal assembly firmly into the rear of the combustion chamber as shown below in Fig 5 e Drill 3 off holes through outer flue pipe and into the mounting spigot and screw flue pipe and terminal assembly...

Страница 10: ...d side of the product when viewed from the front It is therefore suitable for rear or right hand side gas supply See Fig 7 below 10 Rear gas supply route Position of Mortar or Fire Cement Seal around...

Страница 11: ...ages 15 to 17 NOTE Please ensure that the battery that has been disconnected at the factory prior to packing is re connected The battery is located at the bottom L H S of the combustion chamber attach...

Страница 12: ...terminal could come into contact with people near the building or be subject to damage CFM Europe also recommend the fitting of a flue terminal guard where regulations do not demand that it be fitted...

Страница 13: ...mber by the two hinge clamp brackets as shown below in Fig 11 These are clamped together to form the seal between the glass frame assembly and the combustion chamber NOTE Always ensure that a consiste...

Страница 14: ...tion centrally in the combustion chamber as shown below in Fig 12 Fig 12 b Fit the front ceramic coal form in front of the burner as shown below in Fig 13 Ensure that the front ceramic coal form is co...

Страница 15: ...b for a few seconds whilst the air is purged from the supply pipe Bring the knob back to its start position and turn it several times to the pilot position The pilot should light Hold in the control k...

Страница 16: ...put between high and low f Check that the gas pressure is 20 0 mbar 1 0mbar 8 0 in w g 0 4 in w g with the main burner operating on high To turn off the main burner g Turn right hand control knob cloc...

Страница 17: ...CED THIS IS NORMAL AND DOES NOT EFFECT OR IMPAIR THE SAFETY OF THE APPLIANCE 3 3 FITTING OF THE FENDER Warning Please take care whilst handling the fender as it s cast iron construction means it is a...

Страница 18: ...page 17 4 1 3 Remove the glass frame assembly from the fire as shown in section 2 8 on page 13 4 1 4 Remove the ceramic coal forms from the combustion chamber taking care not to damage them 4 1 5 Rem...

Страница 19: ...n in section 2 8 on page 13 4 4 4 Remove the ceramic coal forms from the combustion chamber taking care not to damage them 4 4 5 Loosen the pilot pipe disconnect the ignition lead from the electrode a...

Страница 20: ...Flavel Stockist whose details can be found on the CFM Europe website in the stockist section Control Valve B 82290 Pilot Body 70 36250 Thermocouple 70 36270 Pilot Gasket 70 35220 Ignition Electrode 7...

Страница 21: ...Supplied By www heating spares co Tel 0161 620 6677...

Отзывы: