background image

LIGHTING WITH A SPILL

Important do not light with a wax taper

In the unlikely event of the piezo ignition unit failing to light the fire, turn the control

knob to the OFF position, and wait a minute or so for the gas to disperse. The fire

can then be lit by using a spill.

a)

Remove the front casting by lifting upwards. Apply a lighted spill

at the pilot tip. Light the pilot by depressing the control knob at the “off”

position and turn anti-clockwise (with the control depressed) to the

second position marked *.

b)

When the pilot lights, remove the spill and continue to hold the control

knob down for 10 seconds.

c)

If the pilot fails to light, repeat the ignition sequence and hold in the

control knob for slightly longer.

d)

When the pilot has lit, refit the front casting, release the control knob

from the depressed position, depress slightly again and turn the control

anti-clockwise to the high position.

WARNING: The front casting MUST be fitted prior to turning the control knob

from the pilot position.

WARNING : Before attempting any cleaning operation ensure that the fire

has been allowed to fully cool.

CLEANING THE CASE.

Dusting is normally all that is required. But where extra cleaning is necessary, use

a damp cloth.

25

Note : Prior to replacing the oxypilot on this product due to suspected

failure of the component, please remove all debris that has collected on

the lint guard of the oxypilot itself.

Содержание EmberGlow Classic FEMC00EN

Страница 1: ...Installation Maintenance User Instructions Hand these instructions to the user Model No FEMC00EN is for use on Natural Gas G20 at a supply pressure of 20 mbar in G B I E Model No FEMC00EP is for use...

Страница 2: ...Section 2 2 1 Packing Check List 9 2 2 Installation of Fire 9 10 2 3 Fitting Canopy Rear Trim 11 2 4 Fitting Canopy to Firebox 11 2 5 Fitting Spigot to Firebox 12 2 6 Gas Tightness 12 2 7 Fitting the...

Страница 3: ...box Dimensions with case fitted Width with fender fitted 675mm Height with feet fitted 710mm Depth with fender fitted 335mm Height to top of the flue spigot 490mm with feet fitted Gas Connection 8mm c...

Страница 4: ...Flues 5 B S 1251 Open Fireplace Components 6 B S 715 Metal Flue pipes for Gas Appliances 7 B S E N 1858 Chinmeys Components Concrete Flue Blocks 8 B S 7566 Installation of factory made Chimneys Ventil...

Страница 5: ...s not project more than 150 mm If the shelf overhangs more than 150 mm the distance between the fire and the shelf must be increased by 25 mm for every 25 mm of additional overhang over 150 mm 1 5 SID...

Страница 6: ...during or after the smoke pellet test and it is important to check inside upstairs rooms adjacent to the chimney flue Check the chimney pot terminal and general condition of the chimney brickwork or...

Страница 7: ...may be fitted if necessary providing that a minimum clearance 50mm between its open end and nearest obstruction is always maintained Fig 1 Chimney Catchment Space 1 8 2 Fitting to Pre Fabricated twin...

Страница 8: ...h The hearth material must be a minimum thickness of 13 mm with the outer perimeter of the hearth panel at least 50 mm above the floor level to discourage the placing of carpet or other floor covering...

Страница 9: ...ft the glass panel upwards and lift away See Fig 2 Fig 2 Remove the Glass Panel b Grasp sides of the of the glass panel and pull lower edge forward c Remove the coal fuelbed packs that have been retai...

Страница 10: ...there is a definite flow into the opening then proceed with the installation If there is not a definite flow into the opening pre heat the chimney for about two minutes and retest for flow If there s...

Страница 11: ...ia the four fixings screws 2 off L H 2 off R H as shown below in Fig 4 Fig 4 2 4 FITTING THE CANOPY TO THE FIREBOX a Secure the canopy to the firebox with the four screws 2 off L H 2 off R H as shown...

Страница 12: ...air purposes Before making the final gas connection thoroughly purge the gas supply pipe work to remove all foreign matter otherwise serious damage may be caused to the gas control valve on the fire 2...

Страница 13: ...TERY a The battery holder is located at the bottom R H S of the fire unscrew the cap fit the AA battery supplied in the loose items pack and re fit the cap See Fig 7 below Fig 7 13 Spark Generator AA...

Страница 14: ...g 9 The coal form has the individual placement letters stamped on the bottom face Fig 9 14 Coal Form A NOTE The position of the fuel bed components are critical to the performance of the product There...

Страница 15: ...Fig 10 d Fit coal C onto the fuelbed base in the position as shown below in Fig 11 The coal form has the individual placement letters stamped on the bottom face Fig 11 e Fit coal D onto the fuelbed b...

Страница 16: ...und the appliance before and after working on the appliance When replacing these articles we recommend that the replaced items are not broken up but are sealed within heavy duty polythene bags clearly...

Страница 17: ...trol knob from the depress position depress slightly again and turn the control anti clockwise to the high position and check for clearance of combustion products as detailed below IMPORTANT THE FIRE...

Страница 18: ...fully warm up During this time a slight odour may be noticed this is due to the newness of the fire and will soon disappear 3 4 Final Check a Recheck the operation of the fire on all settings b Make...

Страница 19: ...arried out 4 1 GENERAL ACCESS FOR SERVICING 4 1 1 TO REMOVE THE UPPER CANOPY GLASS PANEL a Prepare work area lay down dustsheets etc Disconnect the appliance from the gas supply b Remove the four cano...

Страница 20: ...CONTROL TAP FROM THE FIRE a Disconnect the appliance from the gas supply b Remove the burner assembly as shown in section 4 2 c Disconnect the pilot pipe inlet pipe valve to injector pipe and push fi...

Страница 21: ...n lead c Replacement new ODS in reverse order and carry out a gas tightness test PARTS SHORTLIST Replacement of any parts must be carried out by a competent person such as a GAS SAFE registered gas in...

Страница 22: ...is normally required for this appliance when installed in G B When installed I E please consult document I S 813 1996 Domestic Gas Installation which is issued by the National Standards Authority of...

Страница 23: ...fire opening and the chimney or flue visually checked for fallen debris or blockages which must be removed The chimney should also be checked to ensure clearance of flue products During the annual se...

Страница 24: ...h a spillage monitoring system which shuts down the fire if the evacuation of combustion products from the fire is affected by a partially or fully blocked flue If this system operates the fire will g...

Страница 25: ...econds c If the pilot fails to light repeat the ignition sequence and hold in the control knob for slightly longer d When the pilot has lit refit the front casting release the control knob from the de...

Страница 26: ...w in Fig 2 The coal form has the individual placement letters stamped on the bottom face Fig 2 26 Coal Form A NOTE The position of the fuel bed components are critical to the performance of the produc...

Страница 27: ...3 The coal form has the individual placement letters stamped on the bottom face Fig 3 d Fit coal C onto the fuelbed base in the position as shown below in Fig 4 The coal form has the individual place...

Страница 28: ...tamped on the bottom face Fig 5 f Fit coal E onto the fuelbed base in the position as shown below in Fig 6 The coal form has the individual placement letters stamped on the bottom face Fig 6 Ensure th...

Страница 29: ...g is not required when handling these articles but we recommend you follow the normal hygiene rules of not smoking eating or drinking in the work area and always wash your hands before eating or drink...

Страница 30: ...evelopment the exact accuracy of descriptions and illustrations cannot be guaranteed Part No B 138550 Issue 2 BFM Europe Ltd Trentham Lakes Stoke on Trent Staffordshire ST4 4TJ Telephone General Enqui...

Отзывы: