REPLACING THE BATTERY (SLIDE CONTROL MODELS ONLY)

ENSURE THE FIRE IS COOL BEFORE REPLACING BATTERIES

Unscrew Battery retaining cap situated at the front right of the fire and remove

battery. Replace in the reverse order using a 1.5V AA Alkaline Battery.

It is

important that only an alkaline battery is used, otherwise premature battery

failure and leakage may result.

. Unscrew Battery retaining cap situated at the

front right of the fire and remove battery. Replace in the reverse order using a

1.5V AA Alkaline Battery.

It is important that only an alkaline battery is used,

otherwise premature battery failure and leakage may result.

SPILLAGE MONITORING SYSTEM

This appliance is fitted with a spillage monitoring system which shuts down the fire

if the evacuation of combustion products from the fire is affected by a partially or

fully blocked flue. If this system operates the fire will go out. If this occurs, leave

the fire for at least three minutes then follow the lighting procedure as described in

the previous section.

In the event of repeated operation a CORGI registered

gas installer must be called to investigate and rectify the cause.
CLEANING - WARNING

Before attempting any cleaning operation ensure that the fire has been allowed to

fully cool.
CLEANING THE TRIMS AND PAINTED METAL PARTS
Dependent upon the trim option chosen for use with this fire, there is a variety of

methods that can be chosen to clean the trim. If a Brass trim was supplied with

this fire this is plated brass and this trim must only be cleaned using a clean damp

cloth. Metal polishes must not be used on these trims. If a black trim was

chosen, then these should only be cleaned using a clean, damp cloth also. The

trim is best cleaned by removing it from the fire and placing it face up on a flat

surface. The fender that was supplied with the fire is laquered to protect the

finish and therefore must only be cleaned using a clean damp cloth.

Abrasive cleaners, chemical cleaning agents or any type of polish must

never be used as damage to the finish may result.

CLEANING THE FUEL BED

We do not recommend cleaning of coals or fuelbed components as these are

fragile and damage may result.

None of these parts must be washed or

exposed to any cleaning agents or water

. Any damaged parts must be

replaced by contacting your dealer or telephoning Flavel Fires on the number

stated on the rear cover of this book. Coals must only be replaced with a

complete and genuine replacement set and the fire must never be run with the

wrong number or damaged coals. The fuelbed must be carefully re-assembled as

stated in the following section.

8

Содержание Calypso FNCN**SN Series

Страница 1: ...by the user before operating the appliance and retained for future reference Model No s FICC MN FICC SN FICC RN FDCN SN FNCN SN are only for use on Natural Gas G20 at a supply pressure of 20 mbar in G...

Страница 2: ...I S 813 1996 Domestic Gas Installation which is issued by the National Standards Authority of Ireland Any purpose made ventilation should be checked periodically to ensure that it is free from obstruc...

Страница 3: ...s important that this appliance is serviced at least once a year by a CORGI registered gas installer and that during the service the fire is removed from the fire opening and the chimney or flue visua...

Страница 4: ...hen the control knob is released repeat the lighting sequence In the unlikely event of a failure of the igniter the fire can be lit as follows Depress the control knob and turn anti clockwise to the p...

Страница 5: ...the unlikely event of a failure of the igniter firstly check the operation of the 1 5V battery and if necessary replace with a AA size alkaline battery It is impor tant that only an alkaline battery...

Страница 6: ...fire and press the small flame button once An audible beep will be heard and the heat input level will reduce to the low setting 4 2kW Press and continually hold the small flame button and the fire w...

Страница 7: ...will now remain in the off position until activated by the remote handset Fig 2 REPLACING THE BATTERIES REMOTE CONTROL MODELS ONLY ENSURE THE FIRE IS COOL BEFORE REPLACING BATTERIES Remove the ashpan...

Страница 8: ...re that the fire has been allowed to fully cool CLEANING THE TRIMS AND PAINTED METAL PARTS Dependent upon the trim option chosen for use with this fire there is a variety of methods that can be chosen...

Страница 9: ...uelbed base is located centrally in the fire box Ensure that the fuelbed base fit fully down onto the fuel bed support and is not lodged on the burner See fig 3 below Fig 3 b Position the two halves o...

Страница 10: ...e recess s in the front ceramic rail as a guide for placement See fig 5 below Fig 5 d Select four of the large coals and arrange behind the front row of coals ensuring that flame paths as indicated be...

Страница 11: ...he rear of the fuelbed using the ribs in the rear of the fuelbed as a guide for placement See fig 7 below Fig 7 f Select the remaining four large coals and position to fill the gaps at each end of the...

Страница 12: ...is not required when handling these arrticles but we do recommend you follow the normal hygiene rules of not smoking eating or drinking in the work area and always wash your hands before eating or dr...

Страница 13: ......

Страница 14: ...rts are as follows these are available from Flavel Fires who may be contacted at the address shown on the rear cover Fuelbed base B 58690 Fuelbed front rails L H R H B 18730 Replacement coal set B 613...

Отзывы: