Flavel Calypso FNCN**SN Series Скачать руководство пользователя страница 4

The ceramic fuel bed remains hot for a considerable period after use and

sufficient time should be allowed for the fire to cool before cleaning etc.

The fire must only be operated with a fender which meets the criteria described in

the rear of this book.

OPERATING THE FIRE (MANUAL CONTROL MODELS)

The controls are located behind the ashpan cover which is situated behind the

Ashpan / Fender. The controls, comprise a control valve to adjust the gas flow and

a push button piezo igniter. To light the fire proceed as follows:-

1)

Depress the control knob and turn anti-clockwise to the position

marked pilot. Hold in the control knob for a few seconds to allow the gas to

reach the pilot.

2)

Continue to hold-in the control knob and press the igniter button. If the pilot

does not light, continue to press the igniter button until ignition occurs. When

the pilot has lit, continue to hold the control knob in for 5-10 seconds

to allow the thermocouple to heat up, if the pilot goes out when the control

knob is released, repeat the lighting sequence.

In the unlikely event of a failure of the igniter, the fire can be lit as follows :-

Depress the control knob and turn anti-clockwise to the position

marked pilot. Hold in the control knob for a few seconds to allow the gas to reach

the pilot. Insert the tip of a lit taper in behind the front ceramic coals on the left

hand side. This will light the pilot flame. When the pilot has lit, continue to hold

the control knob in for 5-10 seconds to allow the thermocouple to heat up, if the

pilot goes out when the control knob is released, repeat the lighting sequence.

3)

After lighting, turn the control knob in the anti-clockwise direction to the high

position and the main burner will light. It is recommended that for most

efficient performance the fire is allowed to warm up for a few minutes with

the gas control on maximum.

4)

The gas control can be turned clockwise from the maximum position to give

the desired heat output.

WARNING

If the fire goes out for any reason or is turned off and it is

necessary to re-light the fire it is important to allow the fire to cool

for 3 minutes before attempting to re-light it.

4

Содержание Calypso FNCN**SN Series

Страница 1: ...by the user before operating the appliance and retained for future reference Model No s FICC MN FICC SN FICC RN FDCN SN FNCN SN are only for use on Natural Gas G20 at a supply pressure of 20 mbar in G...

Страница 2: ...I S 813 1996 Domestic Gas Installation which is issued by the National Standards Authority of Ireland Any purpose made ventilation should be checked periodically to ensure that it is free from obstruc...

Страница 3: ...s important that this appliance is serviced at least once a year by a CORGI registered gas installer and that during the service the fire is removed from the fire opening and the chimney or flue visua...

Страница 4: ...hen the control knob is released repeat the lighting sequence In the unlikely event of a failure of the igniter the fire can be lit as follows Depress the control knob and turn anti clockwise to the p...

Страница 5: ...the unlikely event of a failure of the igniter firstly check the operation of the 1 5V battery and if necessary replace with a AA size alkaline battery It is impor tant that only an alkaline battery...

Страница 6: ...fire and press the small flame button once An audible beep will be heard and the heat input level will reduce to the low setting 4 2kW Press and continually hold the small flame button and the fire w...

Страница 7: ...will now remain in the off position until activated by the remote handset Fig 2 REPLACING THE BATTERIES REMOTE CONTROL MODELS ONLY ENSURE THE FIRE IS COOL BEFORE REPLACING BATTERIES Remove the ashpan...

Страница 8: ...re that the fire has been allowed to fully cool CLEANING THE TRIMS AND PAINTED METAL PARTS Dependent upon the trim option chosen for use with this fire there is a variety of methods that can be chosen...

Страница 9: ...uelbed base is located centrally in the fire box Ensure that the fuelbed base fit fully down onto the fuel bed support and is not lodged on the burner See fig 3 below Fig 3 b Position the two halves o...

Страница 10: ...e recess s in the front ceramic rail as a guide for placement See fig 5 below Fig 5 d Select four of the large coals and arrange behind the front row of coals ensuring that flame paths as indicated be...

Страница 11: ...he rear of the fuelbed using the ribs in the rear of the fuelbed as a guide for placement See fig 7 below Fig 7 f Select the remaining four large coals and position to fill the gaps at each end of the...

Страница 12: ...is not required when handling these arrticles but we do recommend you follow the normal hygiene rules of not smoking eating or drinking in the work area and always wash your hands before eating or dr...

Страница 13: ......

Страница 14: ...rts are as follows these are available from Flavel Fires who may be contacted at the address shown on the rear cover Fuelbed base B 58690 Fuelbed front rails L H R H B 18730 Replacement coal set B 613...

Отзывы: