Video Menu
Video Menu Organization
18
© 2012 Flanders Scientific, Inc.
Video Menu Functions
Gamma Select
This function allows you to specify the desired gamma response of the monitor in 0.2 step increments ranging
from a gamma response of 1.8 to 2.8 as well as 2.35 and 1.0. The default gamma setting is 2.2, but any se-
lection may be chosen for instant adjustment of the monitor’s gamma response. The monitor will override this
manual selection in DCI-P3 mode (unless SDI Format is set to XYZ) & operate with a 2.6 gamma response.
Attempting to change the value while in DCI-P3 mode will result in the monitor exiting this color space mode.
Log Mode (Also selectable via Function Buttons)
This mode allows for easier on-set monitoring of uncorrected S-Log or C-Log footage by normalizing the foot-
age with an inverse Log gamma response. For both S-Log and C-Log signals you can select from a Standard
or Full mode. In S-Log or C-Log Full the entire latitude of the signal will be shown by the monitor so that no
signal information is clipped, but this can result in a very dark image onscreen. In S-Log or C-Log Standard
modes the signal will be mapped to the monitor in the same way many cameras’ integrated video assist out-
puts would operate. For example in S-Log Standard mode 90 IRE gray from the signal will be mapped to 100
IRE on the monitor. This typically gives you a more useful image to work with, but will clip highlight informa-
tion outside of the monitor’s native display capabilities. The Log Mode selection works in conjunction with the
Gamma Select value so you can specify what gamma value the signal will be normalized to as a target. The
default setting is OFF and you should leave this set to OFF if not monitoring uncorrected S-Log or C-Log.
Color Temperature
Use this function to set the desired color temperature. You can instantly toggle between 3200K, 5000K,
5600K, 6500K, and 9300K. 6500K is the default setting. Please note that in DCI-P3 mode the monitor will
override this manual setting. Attempting to select a Color Temperature setting manually with DCI-P3 mode
active will result in the monitor exiting DCI-P3 color space mode.
Sharpness Level
This function is a peaking level adjustment and produces an effect very similar to a physical aperture adjust-
ment. By adjusting sharpness lower the image will look softer and by adjusting sharpness higher the image
will look sharper. Perceived sharpness may also be affected by video processing and pixel mapping settings
so optimal results may come from using a combination of these various settings.
SD Enhancement
This toggle applies maximum sharpening and video quality enhancement to SD video sources.
Anamorphic De-Squeeze
Toggles between 1.3, 2.0, and 2.0mag HD Anamorphic De-Squeeze ratios. This is used in conjunction with
the Anamorphic De-Squeeze function described in the
Main Menu
Function
Gamma Select
Gamma 2.2
Scopes & VU-Meters
Log Mode
Off
Video
Color Temperature
6500K
Audio
Sharpness Level
Default
Marker
SD Enhancement
Off
System
Anamorphic De-Squeeze
4:3
Alarm
Signal Mode
Auto
OSD
Processing
Normal Mode
GPI
Composite Setup
7.5 IRE
Display Alignment
Component Setup
YPbPr SMPTE/N10
System Status
SDI Format
Auto
Support
Video