Section 5.0 Specifications 

  

5.1   XTD1.5-I Model 

 
Fuel Type 

 

Cordwood 

 
Test Standards     

ULC S628 (CSA B366.2) & UL 1482 residential. 

 

 

 

 

 

 
Heat Output    

Max of 39000 BTU/hr. with EPA test wood BTU/Hr (63% default efficiency).  

 

 

 

Max of 65000 BTU/hr. with seasoned cordwood. 

 
Range   

 

Will vary with usage depending on the type and condition of cord wood. 
 

 
Shipping Weight         370lbs (168kg) 
 
Firebox Volume     

1.8 cu.ft. (0.050 m

3

 
Firebox  Floor Area  21” x 13 5/8”  (533mm x 346mm) 
 
Door Opening Size     17.5” wide x 8” high (445 mm wide x 203 mm high) 
 
Recommended            18” x 6” Dia. (457 mm x 152 mm) if loading sideways 
Log Size 

 

 

 
Flue Outlet             

6”  (152 mm) diameter (vertical) 

 
Optional                  

29” x 44” Faceplate 

Components            

 

 

Содержание XTD1.5-I

Страница 1: ...CY PHASE II CERTIFIED WOOD INSERTS Verified and tested following ULC S628 and UL 1482 Standards by Manufactured by STOVE BUILDER INTERNATIONAL INC 1700 L on Harmel Qu bec Qu bec G1N 4R9 Tel 418 527 30...

Страница 2: ...mage bodily injury or even death Consult your municipal building department or fire officials about restrictions and installations requirements in your area and the need to obtain a permit Keep and sa...

Страница 3: ...resh air kit installation instructions 12 Section 3 0 Operation 13 3 1 Safety Information 13 3 2 Fuel 14 3 2 1 Simple Wood Moisture Test 15 3 3 Notes About First Firing 15 3 4 Lighting A Fire 15 3 5 M...

Страница 4: ...3 XTD1 5 I Dimensions 9 61 64 20 31 32 6 31 64 13 3 8 8 9 32 15 1 32 8 9 64 20 31 32 2615 16 283 8 6 000 13 7 16 Faceplate fully extended toward the back Faceplate fully extended toward the front...

Страница 5: ...4 XTD1 9 I Dimensions 283 8 2615 16 13 7 16 6 000 10 49 64 23 1 32 9 15 13 16 8 61 64 10 57 64 17 11 16 23 3 64 Faceplate fully extended toward the back Faceplate fully extended toward the front...

Страница 6: ...ors and side and back refractory panels are to be removed from the fireplace These parts must be stored nearby and available for retrofit if the insert is ever removed Removal of any parts which rende...

Страница 7: ...ll provide the best performance as well as compensate for poor draft situations caused by large cross sectional chimneys The insert will not work without a positive seal in the chimney Chimneys constr...

Страница 8: ...mm 13 330 mm Shelf B 22 559 mm 22 559 mm Side mantle C 10 254 mm 10 254 mm Top mantel D 29 737 mm 29 737 mm Table 2 1 CLEARANCES COMBUSTIBLE SHELF ADJACENT SIDEWALL H G A SIDE MANTLE TOP MANTLE B C D...

Страница 9: ...USA Convert specification to R value k factor is given with a required thickness T in inches R 1 k x T C factor is given R 1 C Example If the floor protector is 4 brick with a C factor of 1 25 over 1...

Страница 10: ...mum floor protection for combustible floor materials as specified in this manual Floor protection to the front is to be measured from the fuel loading door opening 5 Flame recommends that you install...

Страница 11: ...he room This creates a potential health hazard 3 CONNECTOR INSTALLATION A flue connector may provide acceptable performance however we recommend the use of a chimney liner to ensure satisfactory perfo...

Страница 12: ...d side down on a flat soft non abrasive surface 2 Assemble the faceplate trim attaching the mitered corners with the corner brackets see Figure 2 4 3 Line up the holes of the side and top panels and s...

Страница 13: ...n the rectangular outlet on the side of the unit by gently removing the material held in place by micro joints Use pliers Note The fresh air intake may be installed on the right or left end side of th...

Страница 14: ...e lantern fuel kerosene solvents charcoal lighter fluid or inflammable liquids to start or freshen a fire in the insert Keep all such liquids well away from the insert while it is in use 6 All insert...

Страница 15: ...ed vapour barrier and tight fitting windows and or has any powered devices that exhaust house air e There is excessive condensation on windows in the winter f A ventilation system is installed in the...

Страница 16: ...uality finish Heating the insert too intensely on the first fire will dull and lighten the colour on overheated areas and cause smoke and odour to be emitted into the room To cure the paint the first...

Страница 17: ...partially closed by moving the knob to the left to adjust the intensity of the fire Use Table 3 2 to adjust the draft control to the desired burn rate Draft Settings Burn Rate Draft Setting Low Push...

Страница 18: ...d then burn cleanly without smoldering If the fire smolders without flame re establish a hotter fire before moving the air control to the lower setting A yellow flame burning in the top of the firebox...

Страница 19: ...d and opened draft controls for a couple of hours Good burning techniques will result in clean glass Hand clean the glass only when the fire is out and the insert is cold A light film can usually be c...

Страница 20: ...THE BAFFLE MAY CAUSE UNSAFE AND HAZARDOUS TEMPERATURE CONDITIONS AND WILL VOID THE WARRANTY Contact your local municipal state or provincial fire authority for information on how to handle a chimney f...

Страница 21: ...on removal for XTD1 5 I Figure 4 2 Baffle installation removal for XTD1 9 I MIDDLE AND REAR TUBES FRONT BAFFLE SUPPORT FRONT TUBE WOOL WEIGHT INSULATION BLANKET VERMICULITE BAFFLE FRONT BAFFLE SUPPORT...

Страница 22: ...ck firebricks first and then the bottom firebricks 2 2 4 2 2 6 5 2 2 1 5 1 1 4 X 2 7 8 X 8 1 2 2 2 1 1 4 X 3 3 16 X 3 9 1 1 4 X 2 3 4 X 8 1 2 2 6 2 7 2 5 2 3 2 3 6 7 1 1 4 X 3 9 X 8 1 2 1 1 4 X 4 1 4...

Страница 23: ...a new cotter pin The cotter pin is a hammerlock style and locks into place by hitting the head sharply with a hammer 5 Note that any tube can be replaced without disturbing the baffle Important Notes...

Страница 24: ...ith the fan turned off will also damage the fan The fan must not be overheated Do not disassemble the fan ALTERING OR TAMPERING WITH THE FAN WILL VOID THE WARRANTY 4 7 Removal instructions To remove y...

Страница 25: ...hr with seasoned cordwood Range Will vary with usage depending on the type and condition of cord wood Shipping Weight 370lbs 168kg Firebox Volume 1 8 cu ft 0 050 m3 Firebox Floor Area 21 x 13 5 8 533...

Страница 26: ...wood Range Will vary with usage depending on the type and condition of cord wood Shipping Weight 400lbs 181kg Firebox Volume 2 3 cu ft 0 065 m3 Firebox Floor Area 21 x 16 5 8 533mm x 422mm Door Openin...

Страница 27: ...d the wholesale price of the replacement part All parts and labour costs covered by this warranty are limited according to the table below The manufacturer at its discretion may decide to repair or re...

Отзывы: