![Flame Energy XVR-I SE Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/flame-energy/xvr-i-se/xvr-i-se_installation-and-operation-manual_2302421032.webp)
XVR-I SE Installation and Operation Manual
32
8 The Venting System
8.1
General
The venting system, made up of the chimney and the connecting pipe between the stove
and the chimney, acts as the engine that drives your wood heating system. Even the best
stove will not function safely and efficiently as intended if it is not connected to a suitable
chimney.
The heat in the flue gases that pass from the stove and chimney connector into the
chimney is not waste heat. This heat is what the chimney uses to make the draft that
draws in combustion air, keeps smoke inside the stove and safely vents exhaust to
outside. You can think of heat in the flue gas as the fuel the chimney uses to make draft.
8.2
Suitable Chimneys
Your wood stove will provide optimum efficiency and performance when connected to a 6-
inch diameter chimney flue system. The connection to a chimney having a diameter of at
least 5 inches (Canada only) or no more than 7 inches is permitted, if it allows the proper
venting of combustion gases and that such application is verified and authorized by a
qualified installer. Otherwise, the diameter of the flue should be 6 inches.
To be suitable, a factory-built metal chimney must comply with UL 103 HT (U.S.A.) or ULC
S629 (Canada).
8.2.1 Factory-built
Metal
Chimneys
These are sometimes referred to as ‘high temp’ chimneys
because they have the special characteristics to withstand
the temperatures that can be created by wood burning
stoves. Factory-built chimneys are tested as a system
with all the necessary components for installation. The
instructions provided with the chimney by its manufacturer
are the only reliable source of installation guidelines. To
be safe and effective, the chimney must be installed
exactly in accordance with the manufacturer’s
instructions.
Use only components intended for the
brand and model of chimney you are using. Never
substitute parts from other chimney brands or
fabricate your own components. The chimney must
be a type suitable for solid fuel.
Содержание XVR-I SE
Страница 7: ...XVR I SE Installation and Operation Manual 7 ...
Страница 28: ...XVR I SE Installation and Operation Manual 28 Clearances to combustible materials and floor protection ...
Страница 40: ...XVR I SE Installation and Operation Manual 40 Installation on the bottom AC01337 ...
Страница 45: ...XVR I SE Installation and Operation Manual 45 Appendix 4 Exploded Diagram and Parts List ...