STORAGE BEFORE INSTALLATION

The storage area must not be exposed to vibrations from the 
surroundings of a kind which can give bearing damage. If the storage 
period exceeds 3 months, the belt drive tension should be released 
and the fans should be rotated by hand at regular intervals.

BEFORE STARTING

Do not start the fan if any damper on the inlet or dis charge side are 
closed. The LQLF fan (with forward-curved blades) must not be run 
if it is not connected to the ducting, and the inspection door must be 
closed to avoid tripping of the motor protection. However, the motor 
may be briefly energized with the inspection door open for checking 
the direction of rotation.

Before starting the fan, check that the impeller rotates freely and that 
no objects which may be drawn in and damage the fan have been left 
inside the unit.

When commissioning a new unit, check the belt tension and adjust, if 
necessary, after 30 min. of operation (see below).

If the fan is equipped with steel spring anti-vibration mountings, the 
transport safety brackets must be removed prior to start.

MAINTENANCE

The fan should be inspected and cleaned every 12 months. The 
intervals between service are based on the assumption that the unit 
is in operation for about 2000 hours per 12-month period in a normal 
comfort installation. If the supply and/or exhaust air has a high dust 
content, the unit should be serviced more frequently.

Check the belt tension every 6 months. The fan is accessible through 
the inspection door/panel.

IMPORTANT!

Isolate the power supply and wait until the 
impeller has stopped rotating (approx. 1 minute) 
before inspecting and servicing the fan. There may 
be designs of duct systems that causes wind 
milling which prevents the impeller from being 
stopped. The wind milling must then be prevented; 
1) turn off the power to the fan 
2) close the dampers.

CLEANING

Wipe the fan with a cloth. It is particularly important to keep the 
impeller clean to avoid unbalance and vibration.

Caution! 

Do not use liquids, since these may seep in between the 

sheet-steel joints and will be absorbed by the casing insulation (does 
not apply to casing type LQWA).

BELTDRIVE LQLR AND LQLS

TO ADJUST THE BELT TENSION

The belts must be correctly tensioned to ensure good contact with the 
pulleys. If insufficiently tensioned, the belts may slip, and if excessively 
tensioned, the motor and fan bearings may be overloaded.

When correctly tensioned, the belt deflection L will be 15 mm per 
metre of distance between centres (c/c) when a force P (N) is applied.

The deflection and force should preferably be measured by means of a 
tensiometer, see Fig. 4 and 5. The force P is dependent on the belt type 
as shown in the table below.

The belts should be rechecked after about 30 minutes of operation.

Belt

section

Effective diameter of smaller  

pulley, mm<

P in N/belt

Normal

Max. 

1)

SPZ

67–95

10

15

SPZ

100 

15

20

SPA

90-132

20

27

SPA

140 

28

35

SPB

160-224

35

50

SPB

236 

50

65

SPC

224-355

60

90

SPC

375 

90

120

1)

 Newly fitted belts.

Fig. 2

L

c/c

P

EUL(B,F) 10

Содержание LQLR

Страница 1: ...LS 3 INSTALLATION OF HABASIT FLAT BELT DRIVE 3 MOVING THE MOTOR TO ADJUST THE BELT TENSION 4 BELT PULLEYS 4 GROOVED BALL BEARINGS WITH TAPER SLEEVE 5 DISMANTLING THE PLUMMER BLOCK WITH BALL BEARING 7...

Страница 2: ...st content the unit should be serviced more frequently Check the belt tension every 6 months The fan is accessible through the inspection door panel IMPORTANT Isolate the power supply and wait until t...

Страница 3: ...easure the longest free measurement distance on the belt to the nearest 100 mm The belt must not be in contact with the pulleys along the measurement distance 6 Remove the belt place it on a flat surf...

Страница 4: ...ny anti corrosion agent and make certain that the surfaces are completely free from oil and dirt Fit the bush into the pulley 2 Oil the screws sparingly and loosely screw them into the tapped holes in...

Страница 5: ...ighten the nut by hand so that the shaft bearing and taper sleeve are firmly in contact with one another 4 Mark one of the tab washer tabs which is in line with a slot in the nut Then tighten the nut...

Страница 6: ...M t ut och markera lagrets l ge p axeln x ___ mm Steg 4 Lossa lagrets f stbultar och l t axeln b ras upp av lyftlinan Sp nn lyftlinan vid behov s att fl kthjulet inte r r inloppskonan Lagret r limmat...

Страница 7: ...toppskruv Steg 5 Lagermonteringen r nu klar Kontrollera att fl kthjulet roterar och utf r slutkontroll Fl kt M Nm Fl ktstorlek 080 090 100 27 27 27 5 3 Fl kthjul 5 3 1 Demontering av fl kthjul storlek...

Страница 8: ...e fit T nipples in the hoses to the indicating instrument and connect them to the pressure gauge The air flow can be calculated by the expression q 1 p m3 s k where the value of k is stated on the uni...

Страница 9: ...asing Screen Casing FREQUENCY CONVERTER Connection of the screening conductor shall be made via an EMC approved union in the frequency converter s casing or by using a clamp intended for this purpose...

Отзывы: