background image

FläktGroup 

DC_8658GB   20181214_R0

We reserve the right to make changes without prior notice

SAFETY DIRECTIVES

  Using the air handling unit ......................................................2
  Free space for service and repair work ..............................2

GENERAL INSTRUCTION

  Checking prior to commissioning ...............................................3
 Dismantling/Reassembly..............................................................3
  Sound transmission .........................................................................3
  Lifting and transport .........................................................................4
  Lifting a unit provided with

  lifting device EQAZ-02 .....................................................................4
  Lifting a unit provided with a

  base frame EQAZ-04 .......................................................................5
  Lifting and transport, outdoor version ........................................5
  EQAZ-04 Base frame, Unit sizes 005-090 ...............................6
  Assemblage of the EQAZ-04 in separately

  delivered version ...............................................................................6
  To fit (secure) the unit to the base frame ...................................6
  Mounting on the floor .......................................................................7
  Mounting on the foundation, outdoor version,

  unit sizes 009-090 ...........................................................................8
  Jointing of air handling unit blocks ...............................................9

  Suspended mounting from the ceiling  ....................................12
  Heavy duty installation ..................................................................12
  Suspended installation, hygienic version,

  unit sizes 005-090 .........................................................................13
  Unit stacked on top of one another

  (only for EQGA, EQGB) .................................................................... 14
  Supporting frame for overhangning unit parts ......................15

 

  Vertical mounting.

  The unit must be ordered for vertical installation.

  Unit sizes 005-032 (single deck casing),

  005-008 (double deck casing) ...................................................16
  Mounting on a wall stand .............................................................16
  Mounting on a floor stand .............................................................16
  Installation of the joints, only applies for

  outdoor units .................................................................................... 17
  To dismantle the handles with/without lock .........................18
  To adjust the hinges .......................................................................18
  Connection to the ducting ............................................................19
  Installation principle – Duct fitted to fan outlet ......................19
  Maintenance .....................................................................................19
  Replacement of door seal ............................................................19
  Spare parts .......................................................................................19
  Inspection intervals ........................................................................19

GENERAL INSTRUCTION 

SAFETY DIRECTIVES 

INSTALLATION INSTRUCTION

Содержание EQAZ-04

Страница 1: ...ion unit sizes 009 090 8 Jointing of air handling unit blocks 9 Suspended mounting from the ceiling 12 Heavy duty installation 12 Suspended installation hygienic version unit sizes 005 090 13 Unit sta...

Страница 2: ...d be a service aisle in front of the electrical cabinet this is to be arranged so that the cabinet can be serviced safely in accordance with local electrical safety regulations Planning for work of th...

Страница 3: ...st 5 times the mass of the vibrationisolated object i e the air hand ling unit above and supported on anti vibration mountings If the floor has a light structure its mass and rigidity can be improved...

Страница 4: ...rgerandheavierunitscanberaisedbyusingahand operated form loader on both short sides to avoid damage to the under side of the unit Lifting by means of a forklift truck with extended forks to avoid dama...

Страница 5: ...000 kg Note Lift tubes are only suited for air handling units supplied from Fl ktGroup The lift tubes must only be used for the specific unit that they have been ordered to The lift tubes are adapted...

Страница 6: ...nuts through the angle bracket beam and cross beam to 28 Nm 2 1 150 EUAZ 2 Casing ASSEMBLY OF THE EQAZ 04 IN SEPARATELY DELIVERED VERSION The base frame can be supplied either in assembled or unassemb...

Страница 7: ...n functional components with a drainage facility Lateral and longitudinal position adjustment is most easily performed with a roller crowbar or similar MOUNTING ON THE FOUNDATION OUTDOOR VERSION UNIT...

Страница 8: ...14_R0 Wereservetherighttomakechangeswithoutpriornotice 8 JOINTING OF AIR HANDLING UNIT BLOCKS GENERAL INSTRUCTIONS 20 x 10 mm 15 x 5 mm 1 2 EQGA EQGB 15 3 5 A 1 3 5 B 1 2 1 1 1 1 A 2 1 2 1 B NOTE Inst...

Страница 9: ...n Fl ktGroup DC_8658GB 20181214_R0 Wereservetherighttomakechangeswithoutpriornotice 9 GENERAL INSTRUCTIONS EQGA EQGB 20 x 10 mm 15 x 5 mm 1 2 2 2 2 1 2 2 2 1 C C EQHA EQHB EQGA EQHB EQGB 2 1 2 1 2 1 2...

Страница 10: ...nally NOTE If the unit is ordered with lifting devices they are mounted in the factory After usage they should be removed and discarded The docking devices should be mounted at the same location using...

Страница 11: ...Group DC_8658GB 20181214_R0 Wereservetherighttomakechangeswithoutpriornotice 11 GENERAL INSTRUCTIONS 3 2 4 1 1 Rear side Tip In cases were accesability is limited on the rear side of the unit A thread...

Страница 12: ...or sizes 036 090 Example 1 Retaining flange A max 35 mm along the inspection side unite sizes 005 090 Cut and remove the edge A at the hinge locations to unite sizes 005 090 Retaining flange A max 75...

Страница 13: ...d the stand from hangers Larger units must be equipped with EQAZ 29 flour grating to enable service personel to enter The frame must also be executed so that so that the base panels have either transv...

Страница 14: ...ngth of lower unit and fit a bar for height compensation under the front frame sectiion Fit EQAZ 16 01 1 sealing strip around the opening of the empty section before fitting the upper unit The EQAZ 16...

Страница 15: ...9 SINGLE DECK CASING 005 008 DOUBLE DECK CASING The following supporting surface is required for a vertical arrangement Flat floor or frame made of angle steel for example 50 x 50 x 5 with outer dimen...

Страница 16: ...lded edges of the roof sections meet and secure it by applying light hammer blows to snap it on PG slip clamp to be fitted over the joints between the units supplied PG slip clamp factory mounted Roof...

Страница 17: ...akechangeswithoutpriornotice 17 GENERAL INSTRUCTIONS TO DISMANTLE THE HANDLES WITH WITHOUT LOCK LOCK WITHOUT HANDLE TO ADJUST THE HINGES Back off the screws and shift the hinge in the appropriate dire...

Страница 18: ...s only and provided that the air handling unit has not been disas sembled The order should also state the product code The code can be found on a separate data panel located on the functional compo ne...

Отзывы: