The pressure switch stops the compressor
when the pressure in the tank reaches the
maximum value allowed (8
bar=116psi standard) and starts it
again when the pressure drop to the
minimum value
(6 bar=87psi standard).
Adjust the outlet air pressure opera-
ting on the reducer-filter (Fig.3)
Pressure is shown on the gauge
placed on one side of the regulator.
Pressure adjustment (fig. 4):
1. adjustment of max. pressure (
cut out
)
Max pressure can be adjusted through the
two screws “A” and “B”.
Rotate the screws “A” and “B” clockwise in
order to increase pressure.
2. adjustment of differential
pressure (
cut in).
Differential pressure can be
adjusted through the screw
“C”.
Rotate the screw “C” clockwise
to reduce differential pressure
.
I
Attention
Pressure regolation must be carried out
by skilled personnel only.
Pressostaten stopper kompressoren, når
trykket i tanken når den tilladte
maksimumværdi (8 bar=116psi stan-
dard) og starter den igen, når trykket
falder til minimumsværdien.
(6 bar
=
87psi standard).
Udgangstrykket justeres ved hjælp
af knappen på trykluftregulatoren.
Trykluft er vist på skalaen placeret
på den ene side af tilsynsmyndighe-
den.
Tryk justering (fig. 4):
1. justering af maks. tryk (
cut out
)
Maks. tryk kan justeres ved hjælp af to skru-
er "A" og "B".
Drej skruerne "A" og "B" med uret for at øge
presset.
2. justering af differenstryk (
cut
in).
Differenstryk kan justeres ved
hjælp af skruen "C".
Drej skruen "C" med uret for at
reducere differenstryk.
I
Advarsel!
Tryk regolation skal udføres af kvalifi-
ceret personale.
10