- 5 -
DUCTING
Manufacturers ducting must be used on this heater. Flagro part number
THCP-WD12 (12” x 12 FT Hitex
A MAXIMUM OF 12 FT OF DUCTING ONLY
POWER SUPPLY INDICATOR LIGHT:
The power supply indicator light will help detect any faulty power supplied to the heater
such as; grounding issues, reverse polarity or missing/poor connections.
Warning Light Indications
Green Light ……………… Meets Power Requirements
Solid Red Light………….. Reverse Polarity
Solid Red & Green Light… Ground Issue
ATTENTION: IF SOLID RED & GREEN IS INDICATED, MAKE CORRECTIONS TO
POWER SUPPLY BEFORE TURNING HEATER ON. FAILURE TO DO SO WILL
VOID ANY WARRANTY.
MAINTENANCE:
1. Every heater should be inspected before each use.
2. Heaters must be inspected at least annually by a qualified service person.
3. The hose assembly shall be visually inspected prior to each use of the heater. If it is
evident there is excessive abrasion or wear, or the hose is cut, it must be replaced
prior to the heater being put into operation. The replacement hose assembly shall
be that specified by the manufacturer.
4. The appliance must be kept clear and free from combustible materials, gasoline and
other flammable vapors and liquids.
5. The flow of combustion and ventilation air must not be obstructed. Be sure to check
the fan assembly and ensure the motor and blade are operating properly.
6. Compressed air may be used to keep components free of dust and dirt build up.
Note: Do not use the compressed air inside any piping or regulator components.