15
4.4
Set
User Program parameters
4.4.1
Warnings
a)
Make sure the Operation Mode is adequate before to start the motor.
b)
All the parameters must be set according to the file manufacturer recommendations.
c)
Make sure all the parameters are verified before to start the motor handpiece.
d)
M0-M9 User Programs parameters modified by the user are memorized.
e)
FKG File Systems parameters cannot be modified by the user (refer to Chapter 4.5).
4.4.2
Parameter setting
To modify User Program parameters from the stand-by state:
1.
To select the desired parameter, press the Setting button “P”.
2.
To modify the parameter setting, press the Adjusting button “+”/“-”.
3.
Press the Main button or wait 5 seconds to confirm.
4.4.3
User Program parameters list
Set Operation Mode
Operation modes list: CW, CCW, REC, ATR, EAL
(refer to Chapter 3 for modes description)
Set Working Speed
In continuous rotation modes (CW and CCW), the working speed can be adjusted from
100rpm to 3’300rpm (50rpm increments).
In REC mode, the working speed can be adjusted for 100rpm to 500rpm (50rpm
increments).
In ATR mode, the working speed can be adjusted for 100rpm to 500rpm (50rpm
increments).
In REC and ATR modes, the working speed represents the mean speed of one single
angle movement (speed set for both Forward and Reverse angles).
Set Torque Limit
In CW continuous rotation mode, the torque limit can be adjusted from 0.4Ncm to
4.0Ncm depending on the set speed:
•
100-200rpm Max torque limit : 4.0Ncm
•
250-400rpm Max torque limit : 3.5Ncm
•
450-650rpm Max torque limit : 3.0Ncm
•
700-950rpm Max torque limit : 2.5Ncm
•
1’000-1’450rpm Max torque limit : 2.0Ncm
•
1’500-1’950rpm Max torque limit : 1.5Ncm
•
2’000-3’300rpm Max torque limit : 1.0Ncm
In REC mode, the torque limit can be adjusted from 2.0Ncm to 4.0Ncm depending on
the set speed:
•
100-250rpm Max torque limit : 4.0Ncm
•
300-400rpm Max torque limit : 3.5Ncm
•
450-500rpm Max torque limit : 3.0Ncm
In ATR mode, the Trigger Torque can be adjusted from 0.4Ncm to 3.0Ncm.
In CCW continuous rotation mode, the torque limit cannot be set.