STEP 5

 

 

CONNECTING THE COOKTOP TO GAS

 

 

Because hard piping restricts 

 

 

 

5-7.  When using test pressures greater than 

movement of the cooktop, the use   

 

 

         ½ psig to pressure test the gas supply 

of an A.G.A. certified flexible metal 

 

 

         system of the residence, disconnect the 

appliance connector is recommended 

 

 

         range and individual shut-off valve 

unless local codes require a hard-   

 

 

         from the gas supply piping. When 

piped connection.  

 

 

 

 

         using test pressures of ½ psig or less to 

 

 

 

 

 

 

 

         test the gas supply system, simply 

Never use an old connector when  

 

 

         

isolate the range from the gas supply 

installing a new product. 

If the hard 

 

 

         system by closing the individual shut- 

piping method is used, you must 

 

 

 

         off valve. 

carefully align the pipe; the cooktop 
cannot be moved after the connection 
is made. 

 

To prevent gas leaks, put pipe joint 
compound on, or wrap pipe thread   

 

 

 

*Teflon: Registered trademark of Dupont. 

with Teflon* tape all around male 
(external) pipe threads. 

 

5-1.  Remove the left most burner pan. 
        Locate the pressure regulator left 
        of the rear burner. 
 
5-2.  Install a manual gas shut-off valve 
        in the gas line in an easily accessed 
        location outside the cooktop. Make 
        sure everyone operating the cooktop 
        knows where and how to shut off the 
        gas supply to the cooktop. 

 

5-3.  Install male ½” flare union adapter 
        to the ½” NPT internal thread at 
        inlet of the regulator. Use a backup 
        wrench on the regulator inlet hex 
        to avoid damage. 

 

5-4.  Install male ½” or ¾” flare union 
        adapter to the NPT internal thread 
        of the manual shut-off valve, taking 
        care to use a wrench to back-up the 
        shut-off valve to keep it from turning. 

 

5-5.  Connect flexible metal appliance 
        connector to the adapter on the cooktop. 
        Position cooktop to permit connection at 
        the shut-off valve or vise versa. 

 

 

5-6.  When all connections have been made, 
        make sure all cooktop controls are in the 
        off position and turn on the main gas 
        supply valve. Use a liquid leak detector 
        at all joints and connections to check 
        for leaks in the system. 

Содержание TTN036-7

Страница 1: ...N BURNERS 36 NATURAL GAS MODEL TN036 7 THIS MODEL IS FIELD CONVERITBLE FOR LP PROPANE GAS 36 LP PROPANE GAS MODEL PN036 7 THIS MODEL IS FIELD CONVERITBLE FOR NATURAL GAS IF YOU HAVE QUESTIONS CALL 800 251 7224 8 AM TO 5 PM EASTERN TIME OR VISIT OUR WEBSITE WWW FIVESTARRANGE COM ...

Страница 2: ...f gas cooktop installation Local codes vary Installation electrical FiveStar recommends this product be installed by a connections and grounding must comply with applicable licensed professional codes In the absence of local codes the gas cooktop should be installed in accordance with the National Fuel Gas Code Product failure due to improper installation is not ANSI 223 1 latest edition and Natio...

Страница 3: ...ion and file the appropriate freight claim Do not refuse shipment Responsibility for shipping damage is with the carrier and the dealer or end user Cut the shipping straps then carefully lift the carton up from the cooktop This will help eliminate possible damage Remove unwrap and temporarily lay aside any parts that are not attached to the cooktop Make sure no parts are left in the carton for acc...

Страница 4: ...ps must be level to obtain proper cooking results Built in cooktops must be installed in a cut out and on a level surface as illustrated Cooktops will either be set for use with Natural gas or Propane LP gas The factory orifice setting is indicated by a second alpha prefix letter in the model number The letter T indicates a Natural gas setting The letter P indicates a Propane LP setting IMPORTANT ...

Страница 5: ...ize the possibility of shock hazard from this appliance If the electrical service provided does not meet the above specifications it is recommended that a licensed electrician install an approved outlet DO NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE THIRD GROUND PRONG FROM THE POWER CORD DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE Locate the electric supply within the area shown or within r...

Страница 6: ...with Teflon tape all around male external pipe threads 5 1 Remove the left most burner pan Locate the pressure regulator left of the rear burner 5 2 Install a manual gas shut off valve in the gas line in an easily accessed location outside the cooktop Make sure everyone operating the cooktop knows where and how to shut off the gas supply to the cooktop 5 3 Install male flare union adapter to the N...

Страница 7: ...he igniter will spark and the burner will light the igniter will continue sparking until the knob is turned from the light position First test may require some time while air is flushed out of the gas line Turn knob to OFF Repeat the procedure for each burner Burner flames should be blue and stable with no yellow or yellow tips excessive noise or lifting of the flame from the burner If any of thes...

Страница 8: ...er ignition test Griddle Grill burner ignition test Griddle Grill assembly in position MAKE SURE ALL CONTROLS ARE LEFT IN THE OFF POSITION Date Installed Inspected __________________________________________________ Authorized Installer s Signature _____________________________________________ Please Print Name ________________________________________________________ NOTE Please leave this checklis...

Отзывы: