SAFETY CONSIDERATIONS 

1.  The Air Cleaner is equipped with a grounded plug.  

Do not defeat the purpose of this plug by removing 
the  grounding  pin,  as  this  may  result  in  an 
electrical shock or create an unsafe condition. 

2.  When  the  power  cord  or  plug  is  damaged  or 

frayed, unplug the Air Cleaner from the wall outlet 
and refer servicing to qualified service personnel. 

3.  Do  not  overload  wall  outlets  and  extension  cords, 

as this can result in fire or electric shock. 

4.  Do  not  allow  anything  to  rest  on  or  roll  over  the 

power cord, and do not place the unit where power 
cord is subject to traffic or abuse. This may result 
in a shock or fire hazard. 

5.  Do not attempt to service the Air Cleaner  yourself 

as  opening  or  removing  motor  cover  may  expose 
you to dangerous voltage or other hazards.  Refer 
all servicing to qualified personnel. 

6.  If the Air Cleaner has been dropped or the cabinet 

has  been  damaged,  unplug  the  unit  from  the  wall 
outlet  and  refer  servicing  to  qualified  service 
personnel.  

7.  Unplug the Air Cleaner from the wall outlet before 

cleaning.    Do  not  use  liquid  cleaners  or  aerosol 
cleaners on cabinet. 

8.  Do not use the Air Cleaner near water, i.e. near a 

bathtub,  washbowl,  kitchen  sink,  laundry  tub,  in  a 
wet basement, in the rain or near a swimming pool, 
etc.  
If  liquid  has  been  spilled  into  the  Air  Cleaner, 
unplug  the  unit  from  the  wall  outlet  and  refer 
servicing to qualified service personnel. 

9.  The  Air  Cleaner  has  slots  or  openings  in  the 

cabinet for ventilation purposes, to provide reliable 
operation  of  the  unit,  and  to  protect  it  from 
overheating. These openings must not be blocked 
or covered. 

10.  The Air Cleaner should be operated only from the 

type of power source indicated on the rating label. 
If  you  are  not  sure  of  the  type  of  power  supply  at 
your location, consult your local power company. 

11.  If  the  Air  Cleaner  does  not  operate  normally  by 

following the operating instructions, unplug the unit 
from the wall outlet and refer servicing to qualified 
service personnel. 

WHAT THE HEPA AIR CLEANER DOES 

The  Mobile  HEPA  Air  Cleaner  has  been  designed  to 
remove  particulate  such  as  atmospheric  dust,  coal 
dust, insecticide dust, mites, pollen, mold spores, fungi, 
bacteria,  viruses,  pet  dander,  cooking  smoke  and 
grease,  tobacco  smoke  and  more.  It  also  removes 
odors  (with  Carbon  Prefilter  and  Carbon  VOC  After 
Filter)  and  heavy-duty  odors  and  fumes  (with  optional 
Carbon/Potassium Permanganate VOC Filter). 
 
 

BENEFITS 

Provides a healthier, more comfortable environment 
in the most demanding environments. 
Provides  relief  from  allergies,  asthma,  and  other 
respiratory illness. 
Reduces  housekeeping  time  and  redecorating 
costs. 

HOW IT WORKS 

Air  is  drawn  in  through  the  top  of  the  unit  to  the 
Activated  Carbon  Prefilter  (1  inch  pleated,  activated 
carbon impregnated polyester filter) which removes lint 
and odors before they enter the HEPA filter. 
Smaller  particles  then  pass  through  a  long-life,  HEPA 
(High  Efficiency  Particulate  Air)  Filter  which  captures 
99.97%  of  particles  0.3  micron  (1/84,000  of  an  inch) 
and  larger.  This  6  inch  filter  has  more  than  175  ft²  of 
collection surface area. 
Air  is  then  drawn  through  a  Carbon  VOC  (Volatile 
Organic  Compound)  Filter  (2  inch)  to  remove 
unpleasant  odors  and  gases,  or  an  optional  Carbon/
Potassium  Permanganate  VOC  Filter  to  remove 
noxious  odors  and  fumes  like  formaldehyde,  heptane, 
tetrachloroethylene,  toluene,  etc.  that  are  off-gased 
from  carpets,  cabinets,  furniture,  paints,  pesticides, 
personal care products, cleaners, etc. 
Clean air is discharged from two sides of the unit. 

OPERATING INSTRUCTIONS

 

1.  Remove  the  Air  Cleaner  from  the  box  by  opening 

the top, tipping the box on its side and sliding the 
unit  out.  If  your  unit  has  any  signs  of  damage 
caused  in  transit,  immediately  contact  the  store 
where the Air Cleaner was purchased. 

2.  Remove  all  packaging  from  the  unit.  Keep  the 

shipping  carton  and  packaging  in  case  the  need 
arises to store or transport the unit. 

3.  Tip unit on its side and install casters on bottom of 

unit. 

4.  Install handle on unit with the screws provided. 
5.  Choose a suitable location on the floor that allows 

unobstructed  circulation  from  the  top  and  both 
sides of the Air Cleaner. 

6.  The unit plugs into a regular 120 volt outlet and is 

controlled  by  two  switches  located  on  the  rear 
panel, near the cord. The system switch turns the 
unit  ON/OFF,  while  the  speed  switch  controls  the 
motor speed. 

7.  The  door  must  be  secured  for  the  Air  Cleaner  to 

operate,  as  the  door  is  interlocked  for  safety.    All 
filters  must  be  in  place  for  the  unit  to  operate 
properly. 

WARNING  

Never use the unit without all of the filters in place.  

Содержание FSHEPA600M-3

Страница 1: ...lter removes lint and unpleasant odors to extend life of HEPA Filter Carbon VOC After Filter removes additional unpleasant odors and gases Heavy duty Carbon Potassium Permanganate VOC After Filter optional upgrade removes noxious odors and fumes Easy to change filters Heavy gauge steel cabinet and powder coat paint finish provide durability Two speed fan motor delivers 360 600 CFM of pure air Swiv...

Страница 2: ...iruses pet dander cooking smoke and grease tobacco smoke and more It also removes odors with Carbon Prefilter and Carbon VOC After Filter and heavy duty odors and fumes with optional Carbon Potassium Permanganate VOC Filter BENEFITS Provides a healthier more comfortable environment in the most demanding environments Provides relief from allergies asthma and other respiratory illness Reduces housek...

Страница 3: ...y be vacuumed between changes Use a soft brush attachment when cleaning True HEPA Filter Part W5 0860 3 Replace every 3 5 years The life of this filter depends on the amount of contaminants in the air and the frequency in which the prefilter has been changed Renovations in the home that create wood drywall dust or similar contaminants will shorten the life expectancy of the HEPA filter Note Handle...

Страница 4: ...repairs needed as a consequence of any misapplication negligent handling improper servicing unauthorized alteration or improper operations 3 Failure to start due to voltage conditions blown fuses open circuit breakers or other damages due to the inadequacy or interruption of electrical service 4 Damage as a result of floods winds fires lightning accidents corrosive atmosphere or other conditions b...

Отзывы: