INSTALLATION 

LOCATION 

The HEPA Air Cleaner can be installed directly on 
the return air duct eliminating the need for 
external ducting. The unit can also be mounted on 
the floor, a wall or be suspended from the ceiling 
and with the use of collars, be ducted into the 
return air plenum. Care should be taken to keep 
the unit away from an area where there is a 
possibility of moisture leaking on to it. 

Ensure 

there is at least 15 inches in front of the unit to 
allow removal of the filters and lamps. 
 

GENERAL INSTALLATION STEPS 

(Duct Mount) (see Fig. 1) 

1. Before installing, remove any packaging. 

Open the door and remove the filters. 
Remove the lower panel on the front of the 
unit to remove PCO and VOC filters and the 
lamps and gloves which were packed at the 
bottom of the unit. See Maintenance for 
instructions to remove the filters. 

2.  If the unit is to be mounted on the return air 

plenum, it must be installed after the last 
return branch connection on the plenum. If 
outside air is introduced into the return air 
duct, either through a HRV (Heat Recovery 
Ventilator) or direct, it should be added to the 
system before the intake inlet to the Air 
Cleaner. 

3.  Tape the mounting template level on the 

plenum and proceed to cut and drill the 
necessary holes as marked. 

4.  Remove the plastic film covering the back 

holes and snip the small joints in the middle 
of the mounting flaps on the back of the unit 
as indicated on the template. 

Do not open 

the holes on the top or bottom of the unit 
if you are duct mounting the Air Cleaner.

 

Bend all the flaps outward slightly less than 
90 degrees, except for the upper bottom flap 
which is only bent up 45 degrees. This 
bottom flap will act as a deflector for the 
exhaust air entering back into the plenum.  

5.  Place the gasket material around the two 

openings on the back of the air cleaner.  

6.  Place the unit on the plenum so the flanges 

are placed through the holes cut in the duct. 
Fold all the flanges, except the upper bottom 
flap, over to enclose the duct between the 
flanges and the unit. The upper bottom flap is 
only bent up 45 degrees. 

7.  Secure the unit to the duct with the screws 

provided. 

 

WARNING  

If you are installing this unit directly to the duct without 
using collars, 

DO NOT

 open the top or bottom collar 

mounting holes on the unit. 

Fig. 1 – Duct Mount Installation 

WARNING  

When installing this unit directly to the return duct 
insure there is no exposed plastic or wiring directly in 
line with the exposed light from the lower mounting 
hole on the back of the unit. The UV light will cause 
deterioration to plastic. 

WARNING  

This unit must be installed on the return air side of the 
system only. Do not connect to supply side. 
Do not install in a cooking area or connect directly to 
any appliance.  

CAUTION 

This unit contains sharp edges. Always wear protective 
gloves when handling the unit. 

NOTICE 

This unit has only been painted on the exterior. There 
may be some over spray inside the galvanized steel 
cabinet and this is normal. 

CAUTION 

This unit is not intended for use where there are high 
levels of industrial chemicals present.  

Содержание DM900UV-VO-A

Страница 1: ...traviolet Germicidal Lamps CinQuartz Photo Catalytic Oxidation Filter removes unpleasant odors and Volatile Organic Compounds Carbon Potassium Permanganate Final Filter removes non organic gases Kills or inhibits bacteria viruses mold fungi and microbial growth Easy to change Filters and Lamps Powerful motor delivers 250 CFM of clean sterilized air Heavy gauge galvanized steel cabinet and external...

Страница 2: ...time and redecorating costs Provides a healthier more comfortable environment year round HOW IT WORKS Millions of airborne pollutants are carried through the return air ducts of the heating cooling system The Air Cleaner has been designed to be installed on the return air duct A portion of this return air is by passed through an opening on the rear or top of the unit and passes through a 5 stage f...

Страница 3: ... the holes on the top or bottom of the unit if you are duct mounting the Air Cleaner Bend all the flaps outward slightly less than 90 degrees except for the upper bottom flap which is only bent up 45 degrees This bottom flap will act as a deflector for the exhaust air entering back into the plenum 5 Place the gasket material around the two openings on the back of the air cleaner 6 Place the unit o...

Страница 4: ...r direct it should be added to the system before the intake inlet to the Air Cleaner 5 The 8 inch intake collar top must draw air from the return duct at a location that will be ahead of the clean exhaust air that will be returned to the duct from the Air Cleaner An 8 inch collar will be installed on the return duct and a length of 8 inch flexible hose or duct is required to attach between the 8 i...

Страница 5: ... cord to be placed where it may be walked on or allow anything to roll over it MAINTENANCE For efficient operation the filters must be changed on a regular basis If you notice a reduction in air flow from the system check the filters WARNING Never use the Air Cleaner without all of the filters in place and all cover panels and doors closed Make sure all the screws are in place CAUTION Make sure to...

Страница 6: ...tancy of the HEPA filter Note Handle the HEPA filter by the frame only The paper is fragile and a puncture or tear will reduce efficiency Replacing the UV Lamps PCO Filter and Final Filter 1 To change the PCO filter Final filter and UV lamps turn the Air Cleaner OFF and UNPLUG it Remove the screws from the lamp access panel and remove the panel DO NOT misplace the parts 2 Carefully remove the filt...

Страница 7: ... may still light after 2 years but the intensity of the germicidal wavelength will be reduced UV Lamp PCO Filter Kit DM900 1002 Kit contains 2 UV lamps 2 lamp support clips 1 PCO filter and gloves Dimensions Height Width Depth 29 5 in 16 25 in 12 75 in 74 9 cm 41 3 cm 32 4 cm Intake 14 5 x 3 75 in or 8 in dia 36 8 x 9 5 cm or 20 3 cm dia Outflow 14 5 x 4 37 in or 8 in dia 36 8 x 11 1 cm or 20 3 cm...

Страница 8: ...emoving installing shipping servicing or handling of either defective parts or replacement parts LIMITATIONS OF WARRANTY All implied warranties including implied warranties of merchantability are hereby limited in duration to the period for which the limited warranty is given The expressed warranties made in this warranty are exclusive and may not be altered enlarged or changed by any distributor ...

Отзывы: