CLEANING INSTRUCTIONS

 

The prefilter and collecting cell must be washed on a regular 
basis  for  the  Air  Cleaner  to  function  at  its  peak  efficiency.  
The frequency of cleaning will vary from one environment to 
another,  therefore  the  cell  should  be  checked  monthly  to 
determine cleaning schedule.  On average, the cell should be 
washed every 3 months. 

COLLECTING CELL

 

1.  Turn  Air  Cleaner 

OFF

.    Remove  the  cell  from  the  Air 

Cleaner.    Slide  the  prefilter  and  carbon  filter  out  of  the 
retaining brackets before cleaning. 

2.  Rinse  prefilter and  cell,  and  spray  completely  with  DAX 

Detergent (or non-chlorine, non-corrosive, non-abrasive, 
non-ammonia liquid household detergent).  Let stand for 
5  minutes.    Rinse  well  with  hot  water  (120°F  /  49°C 
maximum). Repeat process 3 times. 

3.  If  dirt  remains,  let  cell  soak  in  a  solution  of  DAX 

Detergent and hot water for 30 minutes. 

4.  For  drying,  place  the  cell  on  a  45°  angle  on  one  end, 

with the arrow pointing sideways, and let stand for 10-24 
hours.    A  hair  dryer  may  be  used  to  speed  up  drying 
time.    Make  sure  the  cell  is  completely  dry  before 
reinserting back into Air Cleaner. 

5.  If arcing or snapping occurs or the lights do not come on 

when  the  cell  is  placed  back  in  the  unit  and  turned  on, 
then remove the cell and allow to dry longer. 

 

 

ODOUR & GAS REMOVAL FILTER 

1.  The  carbon  or  carbon/potassium  permanganate  filter 

must be replaced at regular intervals if odour removal is 
desired (approximately every 3-6 months). 

 

ODOUR REMOVAL FILTERS ARE NOT WASHABLE.

 

2.  When  inserting  carbon/potassium  permanganate  VOC 

filter into unit, grey foam side faces the back. 

CABINET 

1.  Turn Air Cleaner 

OFF

2.  A soft, damp, lint-free cloth may be used to remove dirt 

and  fingerprints  from  painted  surfaces,  grills  and  end 
panels. 

NEVER  USE  AN  ABRASIVE  CLEANER  ON  THE 
CABINET.

 

WARNING 

DO 

NOT 

WASH 

COLLECTING 

CELL 

IN 

DISHWASHER

.

 

Never use any object to clean between the cell plates as 
this may cause damage to the plates or ionizing wires. 
Never place the cell in an oven to dry. 
The edges of the cell may be sharp — handle with care. 

 
 
 
 
 

 
 
 
 
 
 

TROUBLESHOOTING CHART 

The  two  operation  lights  are  also  used  as  the  high  voltage 
fault  indicator.    If  the  fan  is  operating,  but  the  lights  do  not 
come on, then there is a problem in the high voltage circuit.  
To determine what the problem is, turn the Air Cleaner 

OFF

 

and remove the collecting cell.  Close the lid and turn the Air 
Cleaner  back 

ON

.    If  the  lights  come  back  on,  the  problem 

lies in the cell.  Check the cell for wetness from washing or 
look for a broken ionizing wire or bent cell plate. 
 
If  the  lights  do  not  come  on,  the  problem  is  with  the  power 
board or operation light(s).  If you are unable to correct any of 
the above problems, call 1-800-267-8305.

 

 

TECHNICAL DATA

 

PROBLEM 

CAUSE 

Fan does not operate 
Both lights off 

Unit not plugged in 
System switch not 

ON

 

Fan switch not in proper position 
Lid not securely closed 

Green light on 
Red light off 

Negative  ion  switch  not  in 

ON 

position 

Fan operating  
Both lights off 

Cell wet from washing 
Short in cell (see below) 

Cell arcing excessively 

Cell wet from washing 
Cell plate bent 
Cell  dirty  or  large  lint  ball/hair 
caught in cell 
Broken ionizing wire 
Prefilter  is  in  backward  (black 
foam should be visible on outside) 

Air Cleaner vibrating 
excessively 

Unit not sitting on flat surface 

Both lights on 
Cell not collecting dirt 

Cell is in backward (Arrow on cell 
should point towards fan blower) 

Dimensions 

Length 

Width 

Height 

 

20.0 in 
12.0 in 
  5.0 in 

 

50.8 cm 
30.5 cm 
12.7 cm 

Weight 

  18.0 lbs 

  8.1 kg 

Input Voltage 

120 V              60 Hz 

220 V           60 Hz 

220 - 240 V  50 

Hz            

Power 
Consumption 
(maximum) 

 

85 Watts 

 

Air Flow        High 

Medium 

Low 

130 cfm 
  80 cfm 
  60 cfm 

221 m³/hr 
136 m³/hr 
102 m³/hr 

Cell Output Voltage  

6200 VDC @ < 1 mA 

 

Collecting Cell 
Surface 

756 in² 

4877 cm² 

Negative Ionizer 

-5000 VDC @ <.1 mA 

 

Negative Ion 
Output 

327.7 K/in³ 

20 K/cm³ 

Ideal for rooms up 
to:  (for over 3 air 
changes/hour) 

16 x 20 x 8 ft 

320 ft² 

4.9 x 6.0 x 2.5 m 

29.5 m² 

Odour & Gas Filter 
 
 
Prefilter 

Collecting Cell 

DAX Detergent and Carbon 
Filters or Carbon/ Potassium 
Permanganate VOC Filters, 
are available from your 
Dealer.

 

Содержание 585AI-BLK

Страница 1: ...ses tobacco smoke cooking smoke and grease and more down to 0 01 micron Activated Carbon Filter removes unpleasant odours included with Model 585AI BLK Carbon Potassium Permanganate Volatile Organic Compound VOC Filter removes noxious odours and gases included with Model 585AI 2 W Negative Ionizer restores the air s natural ion balance 3 Speed Fan and Performance Indicator Light Ideal for rooms up...

Страница 2: ...ntrol Switch 4 Negative Ion Emitter 5 Lid which activates Safety Interlock 5 The System Switch controls the power to the Fan Control Switch and the power board When the System Switch is ON the green light will be illuminated 6 The Fan Control Switch in the front position is low speed the center position is medium and the rear position is high speed 7 The negative ions are controlled by a separate ...

Страница 3: ...ionizing wires Never place the cell in an oven to dry The edges of the cell may be sharp handle with care TROUBLESHOOTING CHART The two operation lights are also used as the high voltage fault indicator If the fan is operating but the lights do not come on then there is a problem in the high voltage circuit To determine what the problem is turn the Air Cleaner OFF and remove the collecting cell Cl...

Страница 4: ... e beds sofas 12 Do not use the Air Cleaner when oxygen is being used or when combustible gases are present 13 The Air Cleaner has slots or openings in the cabinet for ventilation purposes to provide reliable operation of the unit and to protect it from overheating These openings must not be blocked or covered 14 The Air Cleaner should be operated only from the type of power source indicated on th...

Отзывы: