Optical signalling:
Optical signalling device........................................flash tube W = 3 Ws
Flash frequency.....................................................2 Hz ... 5 Hz
Flash time following end of call
(bridging call pause) ..............................................approx. 4s
Housing
Height x Width x Depth..........................................approx. 150 x 195 x 104 mm
Weight ...................................................................approx.0.9 kg
Operating position .................................................vertical wall mounting
Environmental conditions
Operating ambient temperature ............................-20°C ... +60°C
Transport and storage temperature.......................-20°C ... +85°C
Degree of protection according to IEC 60529 .......IP 66
Insulation class......................................................I
User information
This device is a weatherproof signalling device especially designed for use in rugged in dustrial conditions. Please note
the following warnings and security information:
1. The TWIN-Kombi 5843/5 was disigned in compliance with Insulation class I and may only be connected to and
operated at the voltage it was designed for. The device is not suited for continuous operation. Make sure the
connections are in perfect order. The connecting cable must be laid in a manner not to cause a tripping hazard.
2. The device may only be operated at the given ambient conditions (see also under "Technical data"). Adverse am
bient conditions, as for instance too high or too low ambient temperatures are not allowed, due to increased risk of
an electronic parts breakdown.
3. Make sure the device and the connecting cable(s) are not damaged. If the device is damaged, it may not be
operated.
4. While the device is in operation please follow all relevant legal and professional regulations, the legally required
precautions to be taken to prevent accidents, laws and regulations governing the connection of a device to private
branch exchanges and public telephone networks and the operation of such a device. Only a trained professional
may connect, take in use or maintain this device.
5. In case of repairs, use only original spare parts, which must be changed by trained and skilled personnel. Other
spare parts may cause damage.
6. Disconnect power before opening the device.
7. Take into consideration the required operating position.
8. Continuous use of the device and/or too short a distance between persons and the sound source may cause hearing
damage.
9. External protection devices
The telephone call repeater TWIN S need local power 230VAC for activating the bell and the lamp, the activation
command is made by the analogue telephone line ACB
9.1
Local power 230VAC
The TWIN S must be protected from eventual short circuits or overcharges by external devices, i.e. fuse and
electric switch, to be supplied and installed at installer care.
On the label there are the nominal and maximum absorption values
Nominal absorption: 100mA, 230VAC
Maximum absorption: 150mA, 230Vac
It is suggested a delay fuse 200mA and an electric switch 230VAC, 0.5A
9.2
Telephone activation circuit
The call repeater activation circuit is made by the bell line voltage generated by the telephone central
exchange.
A telephone line protection, i.e. FITRE PR164, must be installed at installer care.