background image

 

Distribution and Maintenance Vertical Technik AG,  

 

Bächliackerweg 6, CH-4402 Frenkendorf, Tel. +41 61 413 28 00

 

 

www.verticalskate.ch

 

 

 

 

 

Maintenance Plan: 

The following maintenance plan is according to DIN 79000. According to DIN 79000, it is the duty 
of  the  customer  to  comply  with  the  following  plan  and  document  all  inspections.  The  person 
performing the inspection should be competent to do so. Any failure may result in the product 
not being according to DIN 79000 and may void warranties. Also adhering to the maintenance 
plan will make your products last longer. Please contact us in case you need any assistance. 

The inspection is divided into three parts depending on the frequency of the inspection; weekly 
routine, monthly operational and annual inspection. The frequency of the inspections should be 
increased in areas where there is more frequent use, where there is more vandalism and areas 
that are close to the sea. For example it may be a good idea to do a daily inspection instead of a 
weekly inspection in a heavily used area such as a school.  

To  prevent  any  accidents  and  damages,  defects  that  are  detected  should  be  repaired 
immediately. It may be a good idea to close the product to public use before necessary repairs 
are done. Please contact Flopark for any help or any spare parts requirements. 

Weekly routine inspection: 

 

Check for obvious signs of damage, such as broken parts, missing parts, sharp edges. 

 

Check for loose bolts. 

 

Make sure the foundation is not exposed. 

 

Check moving parts to make sure they are in good condition and that the movementis 
smooth. 

 

Check for obvious signs of damage, such as broken parts, missing parts, sharp edges. 

 

Check safety surfacing to ensure that it is not damaged. 

 

Check for any dents or scratches and use touch up paint to cover them. This is toprevent 
rusting. 

 

Check the safety zone around the products to make sure that it is free from any other 
objects and that the surface is clean and free from debris, broken glass etc. 

 

Check the product markings. If removed, or if they cannot be read, ask for replacements. 

Monthly operational inspection: 

 

Repeat the steps for the weekly routine inspection. 

 

Repeat all the moves in the products. Make sure the torsion system works properly. 

 

Check for any excessive wear. Check all fixations. 

 

Check for any signs of corrosion. 

 

Check all bolts to see if any are loose. Retighten if necessary. 

 

Make sure all seats, grips, foot pedals etc. are secure. 

 

If necessary grease bearings. 

 

 

 

Содержание SD13

Страница 1: ...Distribution and Maintenance Vertical Technik AG Bächliackerweg 6 CH 4402 Frenkendorf Tel 41 61 413 28 00 www verticalskate ch 1 Chest and Pull Down Station SD13 Product Manual ...

Страница 2: ...oth sides and push your arms forward for repetitions Please note Only for use by persons 14 years and older Consult a physician before you begin this or any workout rouitne If equipment should become unstable immediately discontinue use and report to authorised personnel Inappropriate use of the equipment could result in personal injury Please follow recommended use and stop if exercise should bec...

Страница 3: ... verticalskate ch 3 SD 13 Chest and Pull Down Station General Information Length 1930 mm Width 860 mm Height 1700 mm Weight 75 KGS Required Safety Zone 4930mm 3680 mm Maximum User Weight 120 KGS Number of Users 2 Persons Torsion System None Muscles Exercised Shoulder back arm chest and abdominal muscle groups ...

Страница 4: ...41 61 413 28 00 www verticalskate ch 4 Safety Zones Safety zones of all products are given in the following pages Please note that the products should be assembled in such a manner that safety zones of the products should not intersect The illustrations given below try to explain this point ...

Страница 5: ...enance Vertical Technik AG Bächliackerweg 6 CH 4402 Frenkendorf Tel 41 61 413 28 00 www verticalskate ch 5 SD 13 Chest and Pull Down Station There are three types of installations that can be done depending on the surfacing ...

Страница 6: ... be repaired immediately It may be a good idea to close the product to public use before necessary repairs are done Please contact Flopark for any help or any spare parts requirements Weekly routine inspection Check for obvious signs of damage such as broken parts missing parts sharp edges Check for loose bolts Make sure the foundation is not exposed Check moving parts to make sure they are in goo...

Страница 7: ...28 00 www verticalskate ch 7 Annual Inspection Perform monthly operational inspection Make sure the products are fixed to the foundations It may be a good idea to remove the post covers and retighten the bolts that fix the structure to the foundation Check the central post for any wear Check all welds ...