MAN-00112 R 2.0 - EasyGrid Base User Guide
12
4.4 Grounding Terminal
This terminal provides an additional level of immunity against electromagnetic
interferences.
It should always be grounded trough a low inductive conductor (we recommend
multiple braid 8 AWG copper wire) to insure adequate protection.
4.5 Powering the EasyGrid Base
The EasyGrid Base requires a
24 volts DC (± 5%)
supply. Power consumption: 15 Watts.
FISO recommends the use of Power Supply FISO PN: SEN-PS-EGRID .
The power input terminal block is located at the bottom left of the terminal face panel.
There is no Power Switch per say. As soon as connected, it is energized and powered up.
1.
Connect the unit to the power supply using terminal block connectors V+, V-
2.
Wire the power input terminal block to a power supply providing the required voltage
and power.
Please refer to the power supply operating guide for important notices and installation information.
WARNING
To avoid damage to the unit, make sure that the power fed into the input complies with
technical specifications. No other voltage level or range is accepted.