background image

3

Hear This!

The SA330x amplifier is capable of cleanly reproducing the sound of your 
instrument at very high volume levels. Prolonged repeated exposure to high 
sound pressure levels (SPLs) without protection can cause permanent hearing 
loss. OSHA has set guidelines and specified permissible sound-exposure limits 
for those who work in high SPL environments.

 
Permissible Noise Exposures

Duration per day, hours    Sound level dBA slow response

 

8  

90

 6 

92

 4 

95

 3 

97

 2 

100

 

1 1/2 

102

 1 

105

 

1/2  

110

 

1/4 or less 

115

To ensure against permanent hearing loss, wear hearing protection when you perform with 
amplification. 

This symbol means the product must not be discarded as household waste, and should be 
delivered to an appropriate collection facility for recycling. For more information on disposal 
and recycling of this product, Contact your local municipality, disposal service, or the shop 
where you bought this product. 

FCC Compliance Notice

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a 
residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed 
and used in accordance with the instructions, may cause harmful interference to radio communications. However, 
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause 
harmful interference to radio or television reception, which can be determined by turning the equipment off and 
on, the user is encouraged to try to correct the interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.

NOTE:  Fishman Transducers, Inc. is not responsible for unauthorized equipment modifications that 
could violate FCC rules, and/ or void product safety certifications.

EU Declaration of Conformity CE:

 

Hereby, Fishman declares that this SA330x is in compliance with 

the essential requirements and other relevant provisions of Directive 2014/30/EU, 2014/35/EU. The 
Declaration of Conformity can be found at 

www.fishman.com/support.

Содержание SA330x

Страница 1: ...USER GUIDE SA330x fishman com...

Страница 2: ...llen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 15 Do not expose the apparatus to dripping or splashing liquids and do not plac...

Страница 3: ...reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with t...

Страница 4: ...place that is free of obstructions 2 Loosen the lower of the two large thumbscrews and spread the tripod legs Follow the height warnings printed on the stand for safe operation Figure 1 Setting the h...

Страница 5: ...tlet with the appropriate AC voltage 3 Push in the Mute switch and turn on the Power switch 4 Connect your instrument or other audio source to the Channel 1 input with an appropriate mic or instrument...

Страница 6: ...e the Phase switch to improve low frequency response at low volumes or reduce microphone or instrument feedback at high volumes 6 High Boost highs to add air and presence to your sound With the knob s...

Страница 7: ...7 1 3 5 6 8 10 4 2 7 9...

Страница 8: ...plosives or pops that may occur when using a microphone for speech or vocals 14 Aux In Use this to control the level of a device plugged into the Aux inputs Note that the Aux channel is independent o...

Страница 9: ...9 12 11 13 14 16 17 15...

Страница 10: ...ix output This output is always ground isolated to prevent ground loop hum 24 AC Power Switch AC Power Inlet Connect the supplied detachable AC power cable here and the other end to an AC mains power...

Страница 11: ...tem SA330x Model 494 000 414 Input 100 120V 50 60Hz Max Power 300Watts 2 5A Fuse T5AL 250V CONFORMS TO UL STD 60065 CERTIFIED TO CSA STD C22 2 NO 60065 4006175 Caution for continued protection against...

Страница 12: ...Phase switch also affects the signal polarity to the balanced D I and Monitor outputs synchronizing the amplifier with other sound systems in use Anti Feedback The Anti Feedback control is a variable...

Страница 13: ...Wait 10 seconds for the device to become operational before disconnecting and reconnecting In order to provide the safest operation of your SA330x the Accessory port features fault handling during pow...

Страница 14: ...CATORS RING REVERB MUTE TIP TIP LEFT RING RIGHT AUX INPUTS 1 4 AUX LEVEL 1 8 PHANTOM POWER ACCESSORY PORT 48V CH 2 PHASE CH 2 BALANCED D I OUTPUT CH 2 MIC INPUT MIC PREAMP 18dB INPUT BUFFER HI PASS 30...

Страница 15: ...und isolated Sub Output Output Impedance 600 Ohm balanced Phantom power tolerant ground isolated Speaker System Woofer Six 4 patented dual gap with neodymium magnet Tweeter 1 soft dome neodymium magne...

Страница 16: ...fishman com Fishman and Fishman Transducers are trademarks or tradenames of Fishman Transducers Inc 513 300 234_r2 7 16...

Отзывы: