Lit. No. 48685, Rev. 00
2
February 15, 2010
49900
Control Functions
Raise, Lower, Float, Angle
Moving the control lever in straight lines up and down
or from side to side on the control body will result in
the following blade movements:
Note: If control function times out before desired
blade movement is complete, release the lever
to the center position, then move back into the
desired function.
Function Time-Outs
All control functions, except LOWER/Float, time out
(stop) automatically after a period of time. This is to
limit the amount of electrical energy required from the
vehicle.
While the operation of the XLS™ and XtremeV™
controls are the same, the time-outs vary.
Note: If control function times out before desired
blade movement is complete, release the lever
to the center position, then move back into the
desired function.
Automatic Shutdown
The control will automatically turn OFF after being
idle for 20 minutes. To reactivate the control after a
shutdown, move the ON/OFF switch to OFF, then back
to ON.
Smooth Stop
The control automatically allows the blade to coast to
a stop when the lever returns to center position. This
results in smoother operation, reduces shock to the
hydraulic system and increases hose and valve life.
Control Lever Movement
From the center position, the control lever can be
moved in one of eight (8) directions to control various
movements of the snowplow blade. To change from
one movement of the blade to another, the control
lever must be moved back to the center position
before selection the desired function. Whenever the
lever is released, it should spring back into the center
position to stop any blade movement.
L
R
RAISE
LOWER
ON/OFF
FLOAT
SCOOP
RETRACT
U.S. PAT. 4,999,935
2
1
3
WING
IN/OUT
4
WING
IN/OUT
Float Light
(green)
Function
Description of Operation
RAISE
Move control lever toward top of control
body to raise snowplow and cancel FLOAT
mode. Function times out after 3.5 (XLS) or
4.0 seconds (XtremeV).
LOWER
Move control lever toward bottom of control body
to lower snowplow. Release the lever to stop
blade at desired height.
FLOAT
Move control lever to
LOWER
position and hold
for 3/4 second to activate this mode. FLOAT
indicator light in upper right corner of control face
will illuminate. Blade will lower to ground surface
and follow contour of surface as it dips or raises.
Function does not time out; however, control will
shut down after 20 minutes of nonuse.
Press
RAISE
button momentarily to cancel FLOAT.
L
(Angle
Left)
With wings in a straight line, move control
lever straight to the left to move both wings
to angle left position. Left wing retracts while
right wing extends to cast snow to driver's left
side. Function times out after 3.25 (XLS) or
3.0 seconds (XtremeV).
R
(Angle
Right)
With wings in a straight line, move control
lever straight to the right to move both wings to
angle right position. Right wing retracts while
left wing extends to cast snow to driver's right
side. Function times out after 3.25 (XLS) or
3.0 seconds (XtremeV).
1
&
4
Used to access the SECURITY GUARD™
system activation mode.
2
&
3
Used to clear the SECURITY GUARD™ system
activation mode.