background image

2

FACTORY PRESET ‘TURN-ON-AND-GO’ MARKS

Your Fisher M-96 is fairly simple to operate, especially when

compared to other metal detectors. Even so, we strongly

recommend that you read this entire manual. You’ll be able to tune

your M-96 to your specific needs and conditions.

But if you just can’t wait any longer, and you’re an experienced

detector user, here’s some quick instructions to get you going:

1. Unpack your M-96 carefully, and save the box. It

may come in handy if you need to ship the instrument.

2. Take a look inside the lock nut on the upper

handle to see if the yellow locking pad is on the

left-hand side for a lower handle with a flat on one

side. Loosen the locking nut by rotating it fully

counterclockwise. This is the configuration for all

M-96’s up to Serial #62230. Units with Serial #62231

and after have a locking pad at the top and a

round lower stem with a stem lock button fitting in

one of the holes at two (2) inch intervals on the

back side of the upper handle.

3. Slip the lower stem into the upper handle, making

sure the flat side of the stem is aligned with the

locking pad inside the lock nut, (Serial No. 62230

and before).

4. Adjust the stem length and coil angle so that the

search coil rests flat on the ground about 6-12

inches in front of and slightly to the right of your

right foot (to the left of your left foot for left handers).

Your arm should be straight and relaxed, the grip

held loosely. The stem length is adjusted by

loosening the nylon wing nut on the search coil.

NOTE: Remember, the longer the shaft, the more you’ll

have to bend your elbow to keep the coil off the ground

and the sooner your arm will get tired. The M-96 is balanced

for comfortable searching in a tight semicircle around
the front of the operator.

CONDENSED OPERATING INSTRUCTIONS

Содержание M-Scope M-96

Страница 1: ...M 96 Operating Manual Value Pedestal and Box Locator F I S H E R R E S E A R C H L A B O R A T O R Y...

Страница 2: ...re pg 4 Setting Up pg 6 Fitting The Detector To the Operator pg 6 Normal Mode pg 7 High Mode pg 8 Control Panel pg 9 On Off Grond Knob pg 9 Mode Knob pg 9 Retune Button pg 9 Headphone Jack pg 10 Searc...

Страница 3: ...field utility use The entire VLF Very Low Frequency operation of the M 96 has been reduced to just two control knobs and a pushbutton Adjusting these knobs gives the operator maximum depth while elim...

Страница 4: ...Serial 62231 and after have a locking pad at the top and a round lower stem with a stem lock button fitting in one of the holes at two 2 inch intervals on the back side of the upper handle 3 Slip the...

Страница 5: ...don t wrap it so tightly that it pulls against the housing or the coil 6 Reconnect the coil cable to the control housing Be careful not to cross thread it and make sure it s snug but hand tighten only...

Страница 6: ...es an accessory into the headphone jack if you don t use headphones you can use the built in speaker Remove protective plug and insert the headphone plug to hear target signals Watch the meter and lis...

Страница 7: ...a target 13 Keep the search coil parallel to the ground 14 When you get a good repeatable signal in your headphones and on the M 96 meter pinpoint the target by passing the search coil over it both s...

Страница 8: ...losest for your best operating length After adjusting the length of the shaft tighten the lock nut with your hand Refer to the photo on page 4 Never use pliers or other mechanical force to tighten thi...

Страница 9: ...s and nails will be ignored 1 Hold the search coil 3 feet off the ground and away from any metal objects 2 To test the batteries turn the MODE knob to BAT and turn the GROUND knob to 5 The meter shoul...

Страница 10: ...l set the search coil flat on the ground turn the GROUND knob to 4 and push and release the RETUNE button Now raise the coil 12 inches from the ground and repeat steps 4 and 5 making minor adjustments...

Страница 11: ...dication that the search coil is close to metal Mode Knob The Mode Knob has three positions HIGH NORMAL and BAT for battery testing Use HIGH sensitivity when searching for smaller and or deeper object...

Страница 12: ...slow half circle motion from side to side and with the coil as close to the ground as possible When the M 96 search coil passes over a conductive metallic object it will be indicated by an increase i...

Страница 13: ...iform depth penetration 4 Search slowly and systematically Pay attention to where you are going and where you have been 5 During your search the meter reading should remain at about 10 for maximum sen...

Страница 14: ...gnal once again Your target should be directly below the center of the search coil 5 For quick and accurate pinpointing of strong signals push the RETUNE button momentarily close to but not over the t...

Страница 15: ...he top end of the stem Grasp either side of the M 96 battery compartment by the top and bottom edges Slide the cover about half way off toward the opposite end of the detector Grasp the nylon pull tap...

Страница 16: ...quency 450 Hz Power Supply 9V each consists of 12 x 1 5V AA batteries in 2 6 battery packs Power Consumption 9V 13 8 mA 9V 8 mA min 7 5 18 5 mA audio threshold 5 0 mA max Threshold 50 mA max sound Bat...

Страница 17: ...15...

Страница 18: ...lief with a 2 year limited warranty Warranty may vary out side the United States See your dealer for details S E R V I C E Fisher is committed to providing you our valued customer with superior servic...

Отзывы: