10.Troubleshooting
10.1 Display board
1
2
3
4
5
6
Infrared Signal
Receiver
1: AUTO indicator
2: TIMER indicator
3: PRE.-DEF. Indicator
4: DIGITAL DISPLAY indicator
5: OPERATION indicator
6: SLEEP indicator
10.2 For all heat pump model
Failure phenomenon
Operation lamp
Timer lamp
Indoor fan speed has been out of control for over 1 minute
☆
X
Indoor room temp. or evaporator sensor is open circuit or short circuit
☆
On
Over current protection of the compressor occurs 4 times
X
☆
EEROM error
On
☆
No over-zero signal
☆
☆
r
Extinguish
☆
Flash at 5Hz
21