Fisher Scientific 15-460-10Q Скачать руководство пользователя страница 5

Fisher Scientific

iv

Isotemp Economy Water Bath

Fisher Scientific

Preface

Do You Need Information or Assistance

on Fisher Scientific Equipment?

The Fisher Scientific Sales Group can provide information on pricing and give you

quotations. We can take your order and provide delivery information on major equipment items or
make arrangements to have your local sales representative contact your. Our products are listed on
the internet and we can be contacted through our Internet home page.

1-800-766-7000

Customer Service

www.fishersci.com

To order online

Fisher Scientific Product Service Support  can supply technical information about proper

setup, operation or troubleshooting of your equipment. We can fill your needs for  replacement parts
or provide you with on-site service. We can also provide you with a quotation on our Extended
Maintenance Program for our products.

Whatever products you need or use, we will be happy to discuss your applications. If you are

experiencing technical problems, working together, we will help you locate the problem and, chances
are, correct it yourself...over the telephone without a service call.

When more extensive service is necessary, we will assist you with direct factory trained

technicians or a qualified service organization for on-the-spot repair. If your service need is covered
by the Fisher Scientific Products warranty, we will arrange for the unit to be repaired at our expense
and to your satisfaction.

Regardless of your needs, professional service technicians are available by telephone to assist

you concerning our products Monday through Friday from 8:00 a.m. to 6:00 p.m. Eastern Time.
Please call or fax us at:

1-800-766-7000

Customer Service

1-800-926-1166

Orders Fax

International customers, please contact your local Fisher Scientific distributor.

Содержание 15-460-10Q

Страница 1: ...Fisher Scientific Isotemp Economy Water Baths Installation and Operation Manual 103412 7002200 Rev 5 2010 Fisher Scientific Inc All rights reserved Printed in U S A Isotemp...

Страница 2: ...ransfer to Marietta was 103412 11 2 09 ccs REV ECR ECN DATE DESCRIPTION By Preface Isotemp Economy Water Bath i Models covered in this manual Catalog Number Model Number Specific Information Voltage 1...

Страница 3: ...and poor equipment performance s Caution All internal adjustments and maintenance must be performed by qualified service personnel s Material in this manual is for information purposes only The conten...

Страница 4: ...WEEE and the equipment that has been put on the market after 13 August 2005 This product is required to comply with the European Union s Waste Electrical Electronic Equipment WEEE Directive 2002 96 EC...

Страница 5: ...you with a quotation on our Extended Maintenance Program for our products Whatever products you need or use we will be happy to discuss your applications If you are experiencing technical problems wo...

Страница 6: ...nd Installation 4 2 Filling the Unit 4 3 Controls and Indicators 4 4 Operation 5 1 Power Up 5 1 Setting the Temperature Control 5 1 Setting the Limit Control 5 2 Procedure 2 5 2 Procedure 1 5 2 Emptyi...

Страница 7: ......

Страница 8: ...nds from ambient to 85 C without the cover while the range for Model 102S is from ambient to 70 C Bath temperatures are controlled by a hydraulic thermostat for reliable trouble free operation Dual th...

Страница 9: ......

Страница 10: ...ify the grounded power plug Use only properly grounded outlets to avoid a shock hazard This unit is not rated for use in hazardous atmospheres Do not continue to use the bath if the Temperature Contro...

Страница 11: ...ation and to permit reaching higher temperatures Hot liquids pose a burn hazard Be careful not to reach into the bath when it contains hot liquids Also be careful of steam rising from hot liquids The...

Страница 12: ...85 C model 102S to 70 C Cover closed Ambient to 100 C Uniformity 0 2 C at 37 C 0 5 C at 37 C shallow pan Stability 0 2 C at 37 C with cover Safety Specifications Indoor use only Altitude up to 2000 m...

Страница 13: ...0 3Q 2235 2L 230V 15 460 2SQ 2230 2L 120V 15 460 3SQ 2236 2L 230V 15 460 5Q 2239 105 5L 120V 15 460 6Q 2240 5L 230V 15 460 10Q 2223 110 10L 120V 15 460 11Q 2224 10L 230V 15 460 15Q 2226 115 5L 10L dua...

Страница 14: ...Note If there is shipping damage keep entire shipment intact retaining the carton and all packing material and file a claim with the final carrier Usually the firm will send an investigator to ascert...

Страница 15: ...or air conditioning vents Provide a fume hood if hazardous fumes are anticipated when using the water bath Be convenient to a sink for filling and draining the water bath 2 Install the cover by inser...

Страница 16: ...er depth 3 When closing the cover place the thermometer along the front edge A notch along the front of the cover clears the thermometer and clip with the cover closed 4 For optimum results the same f...

Страница 17: ...e primary control fails Temperature Control Indicator The green indicator illuminates to show when heat is being supplied to the chamber cycles on and off as heat is requester by the controller Limit...

Страница 18: ...n Follow these steps to set the Temperature Control so that it maintains the desired temperature 1 Turn Limit Control knob fully clockwise 2 Turn the Temperature Control to a setting which approximate...

Страница 19: ...minates the green lamp will turn off then quickly clockwise again until the amber lamp turns off the green lamp will come back on 4 Observe a few cycles of the green lamp If the yellow lamp illuminate...

Страница 20: ...the unit into an appropriate disposal container 3 If you have a larger size water bath allow the unit to cool and pump or siphon to empty the unit into an appropriate disposal container 4 Remove the d...

Страница 21: ......

Страница 22: ...or fuse s call Technical Services No heating Temperature of Limit Control not set properly defective heater or control Check settings Always heating Check settings Defective Temperature Control tempe...

Страница 23: ......

Страница 24: ...emp Economy Water Bath 7 1 Fisher Scientific Item Part No Cover 2 liter Plastic Lid 102304 Stainless Steel Lid 1546232Q Cover 2 liter shallow Plastic Lid 107649 Stainless Steel Lid 1546233Q Cover 5 li...

Страница 25: ...28L and Dual Models 102387 Hinge rim for 10 20 liter 102459 Hinge rim for 2 liter shallow HGMX1 Clip thermometer for 2L shallow 102423 Clip thermometer all except 2LS 102424 Pump Siphon 102391 Control...

Страница 26: ...Isotemp Economy Water Bath 8 1 Fisher Scientific Schematic for 230V Units Schematic for 120V Units...

Страница 27: ......

Страница 28: ...For customer service call 1 800 766 7000 To fax an order use 1 800 926 1166 To order online www fishersci com...