- 32 -
Fault Code 22
Door Actuator Open Circuit.
Remedy: (1) Check that the actuator wiring is plugged into the sensor module and
is not open circuit. If faulty, replace.
(2) Replace the sensor module. (Refer to Section 6.36)
Fault Code 23
Door Actuator Movement Interrupted By Low Voltage.
The door actuator movement was interrupted by low voltage (brown out).
Remedy: (1) Ensure mains voltage is 10% and –15% of nominal.
(2) Replace the sensor module, as voltage measurement circuit may be
reading incorrectly. (Refer to Section 6.36)
(3) Replace the motor control module, as it may not be supplying
sufficient power to the sensor module. When display is off,
approximately 24V DC is supplied. (Refer to Section 6.35)
Fault Code 24
Door Actuator Movement Took Too Long.
Remedy: As per fault code 21.
Fault Code 28
Data Retrieval Error Following Loss of Power
Remedy: (1) Switch off the mains power supply to the dryer for at least 10 seconds
and confirm error.
(2) Replace the motor control module. (Refer to Section 6.35)