- 29 -
Fault Code 8
Exhaust Sensor Over Temperature.
The exhaust sensor measures over temperature (fire detection, element short circuit
or low resistance).
Remedy: (1) Check the integrity of the sensor circuit checking particularly for short
circuits. Approximate resistances (+ 10%) at various temperatures
are; 32
o
F (0
o
C) = 33 KOhms, 72
o
F (22
o
C) = 11 KOhms, 104
o
F (40
o
C)
= 5 KOhms. Replace thermistor and harness if out of range.
(2) Check the element integrity in that it switches off when the dryer is
stopped.
(3) Replace the motor control module. (Refer to Section 6.35)
(4) Replace the sensor module. (Refer to Section 6.36)
Fault Code 9
Exhaust Sensor Under Temperature.
The exhaust sensor measures under temperature (open circuit or not plugged in).
Remedy: Refer to steps for over temperature fault (fault code 8) above, but open
circuit likely.
Fault Code 10
24 Volt Supply Measurement Error.
The sensor module measures low voltage on actuator power supply.
Remedy: Replace the sensor module. (Refer to Section 6.36)
Fault Code 11
Lid Lock Open Circuit.
Remedy: Check the lid lock harness and coil. If there is continuity through these,
replace the sensor module. (Refer to Section 6.36)