28
4-Wire Connections
Use approved 4-wire Power Supply Cord or a 4-wire Cable for Direct Wiring as described
on page 25.
1
Remove the terminal block cover plate.
2
Insert the power supply cable with a UL listed strain relief through the hole provided in the cabinet
near the terminal block. Do not tighten strain relief screw until wiring connections are complete.
Note:
a strain relief must be used.
2
strain relief
clamp sections
strain relief
screws
3
Remove center terminal block screw.
4
Remove appliance ground link by removing the ground connector screw (green screw).
3
4
Note: If the appliance is moved back to a 3-wire
installation the ground link must be refitted.
Remove link
5
Connect ground wire (green) of the power supply cord to the ground conductor green screw.
Tighten screw.
6
Connect the neutral wire (white) of the power supply cord to the center terminal screw of the
terminal block. Tighten screw.
7
Connect the red wire and black wire to the upper and lower terminal block screws marked with the
letter L. Tighten screws.
7
6
5
7
8
Refit terminal block cover by inserting the two tabs first on the rear panel of the dryer and secure
cover with securing screw.
9
Tighten Strain Relief screws.
8
9
Содержание SmartLoad DE62T27G