819091D
41
8 DIAGNOSTIC
MODES
To enter diagnostic modes, press and hold the MENU button, then press the UP button for 4 seconds. The
PC temperature will be displayed on the LCD as shown in Diagram A. The actual temperature of the PC is
shown.
Please NOTE all temperatures shown on display are in degrees Celsius.
PC Sensor Temperature
Note: 4.0 shown on display, indicates the temperature of the PC sensor 4.0
0
C (39.2
°
F).
Diagram A
PC Sensor Temperature.
FC Sensor Temperature
Press the UP button once more – FC temperature.
Note: 12.0 min shown indicates the temperature of the FC sensor is -12
0
C (10.4
°
F).
Diagram B
FC Sensor Temperature
Defrost Sensor Temperature
Press the UP button once more – Defrost sensor temperature.
Note: 18.0 min shown indicates the temperature of the Defrost sensor is -18
0
C (0
°
F).
Diagram C
Defrost Sensor Temperature