The appliance should be installed in a room or space with an air supply in accordance with BS 5440-2:2000.
For rooms with a volume of less than 5 m3 : permanent ventilation of 100 mm3 free area will be required.
For rooms with a volume of between 5 m3 and 10 m3 : permanent ventilation of 50 cm3 free area will be required unless
the room has a door which opens directly to the outside air, in which case no permanent ventilation is required.
For rooms with a volume greater than 10 m3 : no permanent ventilation is required.
Regardless of room size, all rooms containing the appliance must have direct access to the
outside air via an openable window or equivalent.
Where there are other fuel burning 5440-2:2000 should be consulted to determine the correct amount of free area
ventilation requirements.
Gas Installation (GB & IE Only)
This cooker uses NATURAL GAS only and cannot be used on any other gas without modification.
This appliance is manufactured for conversion to LPG if required. If the injectors are not supplied
they can be obtained from the After-Sales Service.
Installation & Service Regulations
This appliance must be installed and serviced only by a suitably qualified and registered
person, and in accordance with the current editions of the following standards and
regulations or other locally applicable regulations:
• Gas Safety (Installation and Use) Regulations
• Building Regulations
• British Standards
• Regulations for Electrical Installation
Failure to install the appliance correctly could invalidate any manufacturer’s warranty and lead to prosecution under the
above-quoted regulation.