background image

Fig 4b & 4c

Fig 4d

Moving the Cooker

• Two people must always raise the cooker, as shown, to prevent damaging the adjustable feet.

• Do not lift the cooker by the door handles.

• DO NOT DRAG the cooker. Lift the feet clear of the floor.

https://producthelp.fisherpaykel.com/eu/Cook/Freestanding_Cookers/Dual_Fuel/OR120DDWGX2/User_Guide_OR120DDWG…

Updated: Fri, 07 Feb 2020 03:46:13 GMT

Powered by

6

Содержание OR120DDWGX2

Страница 1: ...form to Fig 3a or 3b The appliance must be kept no less than 200 mm away from any side wall which exceeds the height of the hob surface Fig 3a or 3b The appliance must be housed in heat resistant unit...

Страница 2: ...located on a pedestal provide safety measures to prevent it falling out Assembling the Backguard Installing the backguard is MANDATORY Fig 2 Assemble the backguard as shown in Fig 2 and fix it by scre...

Страница 3: ...er hose which must be visible and easily inspected or using rigid or flexible metal pipe https producthelp fisherpaykel com eu Cook Freestanding_Cookers Dual_Fuel OR120DDWGX2 User_Guide_OR120DDWG Upda...

Страница 4: ...lass 1 Gas connection made using rigid or flexible metal pipe https producthelp fisherpaykel com eu Cook Freestanding_Cookers Dual_Fuel OR120DDWGX2 User_Guide_OR120DDWG Updated Fri 07 Feb 2020 03 46 1...

Страница 5: ...r support surface The cooker is already fitted with six levelling feet Level the cooker by screwing or unscrewing the feet Fig 4d Make sure you follow the instructions in Figs 4a 4b and 4c Bolts are s...

Страница 6: ...vent damaging the adjustable feet Do not lift the cooker by the door handles DO NOT DRAG the cooker Lift the feet clear of the floor https producthelp fisherpaykel com eu Cook Freestanding_Cookers Dua...

Страница 7: ...raising the cooker Fig 5b Incorrectly moving the cooker Fig 5c Incorrectly raising the cooker https producthelp fisherpaykel com eu Cook Freestanding_Cookers Dual_Fuel OR120DDWGX2 User_Guide_OR120DDW...

Страница 8: ...lation requirements Gas Installation GB IE Only This cooker uses NATURAL GAS only and cannot be used on any other gas without modification This appliance is manufactured for conversion to LPG if requi...

Страница 9: ...l Gas Installation to Natural Gas must conform to the Code of Practice etc The supply pressure for Natural Gas is 20 mbar Installation to Liquid Petroleum Gas This appliance must only be connected to...

Страница 10: ...th the cooker in a separate kit to the gas inlet at the rear of the cooker interposing the gasket Check the correct positioning of the connector as shown and always use two suitable spanners Fig 6b 2...

Страница 11: ...into the cable protector C The supply cable must be of a suitable size for the current requirements of the appliance see Feeder cable section following Connect the phase and earth cables to terminal...

Страница 12: ...r Cable Section TYPE H05RR F 230V 3 x 2 5 mm2 Connection with wall box connection Fig 7 c https producthelp fisherpaykel com eu Cook Freestanding_Cookers Dual_Fuel OR120DDWGX2 User_Guide_OR120DDWG Upd...

Страница 13: ...https producthelp fisherpaykel com eu Cook Freestanding_Cookers Dual_Fuel OR120DDWGX2 User_Guide_OR120DDWG Updated Fri 07 Feb 2020 03 46 13 GMT Powered by 13...

Отзывы: