background image

• Assemble the backguard as shown in Fig. 2 and fix

it by screwing the five screws “A”.

Fig. 2

Location

The installation conditions, concerning protection against overheating of the surfaces adjacent to the cooker, must
conform to Fig.3a or 3b.
The appliance must be kept no less than 200 mm away from any side wall which exceeds the height of the hob surface
(Fig. 3a or 3b).
The appliance must be housed in heat resistant units.
The walls of the units must be capable of resisting temperatures of 75 °C above room temperature. Do not install the
appliance near flammable materials (eg. curtains).
If the cooker is located on a pedestal, provide safety measures to prevent it falling out.

https://producthelp.fisherpaykel.com/eu/Cook/Freestanding_Cookers/Dual_Fuel/OR120DDWGFX2/User_Guide_OR120DDW…

Updated: Fri, 15 Jan 2021 11:10:49 GMT

Powered by

2

Содержание OR120DDWGFX2

Страница 1: ...Fig 1 Assembling the Backguard Installing the backguard is MANDATORY https producthelp fisherpaykel com eu Cook Freestanding_Cookers Dual_Fuel OR120DDWGFX2 User_Guide_OR120DDW Updated Fri 15 Jan 2021...

Страница 2: ...exceeds the height of the hob surface Fig 3a or 3b The appliance must be housed in heat resistant units The walls of the units must be capable of resisting temperatures of 75 C above room temperature...

Страница 3: ...and to ensure adequate ventilation the cooker chassis MUST NOT sit directly on the floor a plinth or other support surface The cooker is already fitted with six levelling feet Level the cooker by scre...

Страница 4: ...Fig 4a Fig 4b Fig 4c Fig 4d https producthelp fisherpaykel com eu Cook Freestanding_Cookers Dual_Fuel OR120DDWGFX2 User_Guide_OR120DDW Updated Fri 15 Jan 2021 11 10 49 GMT Powered by 4...

Страница 5: ...adjustable feet Fig 5a Correctly raising the cooker Do not lift the cooker by the door handles Fig 5b Incorrectly moving the cooker https producthelp fisherpaykel com eu Cook Freestanding_Cookers Dua...

Страница 6: ...the room has a door which opens directly to the outside air in which case no permanent ventilation is required For rooms with a volume greater than 10 m3 no permanent ventilation is required Regardles...

Страница 7: ...orrectly could invalidate any manufacturer s warranty and lead to prosecution under the above quoted regulation Gas Connection The installation of the cooker to Natural Gas or LP Gas must be carried o...

Страница 8: ...be crushed or trapped or be in contact with sharp or abrasive edges It should also not be subjected to corrosion by acidic cleansing agents To Connect the Gas Supply 1 Fit the 1 2 BSP female connector...

Страница 9: ...D and into the cable protector C The supply cable must be of a suitable size for the current requirements of the appliance see Feeder Cable section following Connect the phase and earth cables to term...

Страница 10: ...eeder Cable Section TYPE H05RR F 230V 3 x 2 5 mm2 Connection with wall box connection https producthelp fisherpaykel com eu Cook Freestanding_Cookers Dual_Fuel OR120DDWGFX2 User_Guide_OR120DDW Updated...

Страница 11: ...Fig 7c https producthelp fisherpaykel com eu Cook Freestanding_Cookers Dual_Fuel OR120DDWGFX2 User_Guide_OR120DDW Updated Fri 15 Jan 2021 11 10 49 GMT Powered by 11...

Отзывы: