9
ELECTRICAL CONNECTION
Before connecting the cooktop to the mains power supply check that:
z
The domestic wiring system is suitable for the power drawn by the cooktop.
z
The voltage corresponds to the value given in the rating plate.
z
The power supply cable sections can withstand the load specified on the rating plate.
z
Using UL listed wire connectors, connect the 2 black wires together and the 2 red wires
together. Connect the green (or yellow-green) and white cooktop cables to the white
(neutral) wire in the junction box using the UL listed wire connectors
z
Install junction box cover.
z
Using UL listed wire connectors, connect the 2 black wires together, the 2 red wires
together and the 2 white wires together. Connect the green (or yellow-green) ground wire
from the cooktop cable to the green (or yellow-green) ground wire in the junction box
using UL listed wire connectors.
z
Install junction box cover.
CONNECTION
MAX. CURRENT DRAW
MAX. LOAD
VOLTAGE
3 Wire
32A
7800W
120/240 V
4 Wire
34A
7100W
120/208 V
CONNECTION LOCATION
3 WIRE CONNECTION
4 WIRE CONNECTION
connection location
rating plate location
BASE
Black wires
Red wires
White wires
Red wires
Black wires
UL listed wire connector
UL listed wire connector
Junction box
Junction box
Ground wires
White wires
Cooktop 4 wire cable
Cooktop 4 wire cable
UL listed or CSA approved
conduit connector connector
UL listed or CSA approved
conduit connector connector
Home power supply cable
Home power supply cable